Recommended Placement Torque when Tightening an Orthodontic Mini-implant

Overview
Specialty Dentistry
Date 2006 Jan 31
PMID 16441792
Citations 82
Authors
Affiliations
Soon will be listed here.
Abstract

To determine an adequate placement torque for obtaining a better success rate of mini-implants that are screwed into the buccal alveolar bone of the posterior region as an anchor for orthodontic treatment, implant placement torque (IPT) was measured. The subjects were 41 orthodontic patients (124 implants), with an average age of 24.9 years (SD 6.5 years), who had surgery to place titanium mini-implants. The peak value of IPT was measured using a torque screwdriver. The success rate of the mini-implant anchor for 124 implants was 85.5%. The mean IPT ranged from 7.2 to 13.5 N cm, depending on the location of the implants. There was a significant difference in the IPT between maxilla and mandible. The IPT in the mandible was, unexpectedly, significantly higher in the failure group than in the success group. Therefore, a large IPT should not be used always. According to our calculations of the risk ratio for failure, to raise the success rate of 1.6-mm diameter mini-implants, the recommended IPT is within the range from 5 to 10 N cm.

Citing Articles

Exploring the use, perceptions, and challenges of mini-implants in orthodontic practice: a survey study.

Panaite T, Balcos C, Savin C, Olteanu N, Karvelas N, Romanec C Front Oral Health. 2025; 5():1483068.

PMID: 39844864 PMC: 11753234. DOI: 10.3389/froh.2024.1483068.


Relationship Between Laterality of Orthodontic Miniscrew Failure and Clinical Variables.

Ishizaki-Terauchi A, Ishida Y, Okuzawa-Iwasaki M, Shimizu-Tomoda C, Ono T J Clin Med. 2024; 13(23).

PMID: 39685574 PMC: 11642349. DOI: 10.3390/jcm13237115.


Characterizing orthodontic mini-screws in the hard palate of pigs: An experimental and finite-element study.

Valeri C, Aloisio A, Quinzi V, di Stefano G, Marzo G Heliyon. 2024; 10(3):e24952.

PMID: 39668859 PMC: 11637073. DOI: 10.1016/j.heliyon.2024.e24952.


Comparative assessment of the stability of buccal shelf mini-screws with and without pre-drilling- a split-mouth, randomized controlled trial.

Ummat A, Shetty S, Desai A, Nambiar S, Natarajan S Clin Oral Investig. 2024; 28(10):567.

PMID: 39365318 PMC: 11452459. DOI: 10.1007/s00784-024-05925-7.


Insertion torque, flexural strength and surface alterations of stainless steel and titanium alloy orthodontic mini-implants: an in vitro study.

Puls G, Maranon-Vasquez G, Ramos C, Reis C, Dos Reis A, Stuani M Dental Press J Orthod. 2024; 29(2):e2423282.

PMID: 38775601 PMC: 11104944. DOI: 10.1590/2177-6709.29.2.e2423282.oar.