» Articles » PMID: 16409070

Heterodyne Swept-source Optical Coherence Tomography for Complete Complex Conjugate Ambiguity Removal

Overview
Journal J Biomed Opt
Date 2006 Jan 18
PMID 16409070
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Fourier domain (FD) techniques have increasingly gained attention in optical coherence tomography (OCT). This is primarily due to their demonstrated sensitivity of two to three orders of magnitude over conventional time-domain techniques. FDOCT images are subject to two primary sources of artifacts. First, a complex conjugate ambiguity arises because the Fourier transform of the real-valued spectral interferometric signal is Hermitian symmetric. This ambiguity leads to artifactual superposition of reflectors at positive and negative pathlength differences between the sample and reference reflectors. Second, noninterferometric and sample autocorrelation terms appear at dc, obscuring reflectors at zero pathlength difference. We show that heterodyne detection in swept-source OCT (SSOCT) enables the resolution of complex conjugate ambiguity and the removal of noninterferometric and autocorrelation artifacts. We also show that complex conjugate ambiguity resolution via frequency shifting circumvents fall-off induced by finite source linewidth in SSOCT when samples are shifted to large pathlength differences. We describe an efficient heterodyne SSOCT design that enables compensation of power losses from frequency-shifting elements. Last, we demonstrate this technique, coupled with wavenumber triggering and electronic demodulation, for in vivo imaging of the human anterior eye segment.

Citing Articles

Complex conjugate removal in optical coherence tomography using phase aware generative adversarial network.

Bellemo V, Haindl R, Pramanik M, Liu L, Schmetterer L, Liu X J Biomed Opt. 2025; 30(2):026001.

PMID: 39963188 PMC: 11831228. DOI: 10.1117/1.JBO.30.2.026001.


Widefield optical coherence tomography by electro-optical modulation.

Urban D, Novak P, Preciado M, Vettenburg T Biomed Opt Express. 2024; 15(11):6573-6587.

PMID: 39553869 PMC: 11563341. DOI: 10.1364/BOE.540278.


Low-Cost In Vivo Full-Range Optical Coherence Tomography Using a Voice Coil Motor.

Liao X, He L, Duan Z, Tian P, He Y, Deng Q Micromachines (Basel). 2022; 13(10).

PMID: 36295979 PMC: 9609883. DOI: 10.3390/mi13101626.


Optical Coherence Tomography for Ophthalmology Imaging.

Qin J, An L Adv Exp Med Biol. 2021; 3233:197-216.

PMID: 34053029 DOI: 10.1007/978-981-15-7627-0_10.


Stable multi-megahertz circular-ranging optical coherence tomography at 1.3 µm.

Lippok N, Bouma B, Vakoc B Biomed Opt Express. 2020; 11(1):174-185.

PMID: 32010508 PMC: 6968766. DOI: 10.1364/BOE.11.000174.