» Articles » PMID: 1640694

Distinguishing Sympathomimetic Amines from Amphetamine and Methamphetamine in Urine by Gas Chromatography/mass Spectrometry

Overview
Journal J Anal Toxicol
Specialty Toxicology
Date 1992 Jan 1
PMID 1640694
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Derivatives of seven commonly used sympathomimetic amines and two "designer amines" were isolated from urine, separated chromatographically from amphetamine and methamphetamine, and determined by mass spectrometry with selected ion monitoring. The drugs included ephedrine, propylhexedrine, pseudoephedrine, phenylpropanolamine, hydroxynorephedrine, phenylephrine, phentermine, methylenedioxyamphetamine (MDA), and methylenedioxy methamphetamine (MDMA). The drugs were liquid extracted from urine and derivatized by either heptafluorobutyric anhydride (HFBA) or 4-carbethoxyhexafluorobutyryl chloride (4-CB). Because the base peak ions for ephedrine, pseudoephedrine, propylhexedrine, MDMA, and phentermine are identical to methamphetamine (e.g. 254 amu for HFBA) and those for phenylephrine, hydroxynorephedrine, phenylpropanolamine, and MDA are identical to amphetamine (e.g. 240 amu for HFBA), a table of selected ions was developed for all 11 drugs that distinguished amphetamine and methamphetamine from the sympathomimetic amines with either HFBA or 4-CB. The distinguishing ions rely on the ring structure of the different drugs and fragmentation associated with that structure. The 4-CB reagent partially derivatized the hydroxy-containing sympathomimetic amines, while the HFBA completely derivatized all the sympathomimetic amines. Furthermore, false positive results for the 4-CB reagent were found only for methamphetamine (20-2250 ng/mL of methamphetamine) when high concentrations (greater than 5 micrograms) of ephedrine or pseudoephedrine were present in the specimen. These results are related to a combination of injection port temperature and cleanliness of the injection port sleeve.

Citing Articles

Mass Spectral Library Quality Assurance by Inter-Library Comparison.

Wallace W, Ji W, Tchekhovskoi D, Phinney K, Stein S J Am Soc Mass Spectrom. 2017; 28(4):733-738.

PMID: 28127680 PMC: 5439505. DOI: 10.1007/s13361-016-1589-4.


Enhanced methamphetamine metabolism in rhesus macaque as compared with human: an analysis using a novel method of liquid chromatography with tandem mass spectrometry, kinetic study, and substrate docking.

Earla R, Kumar S, Wang L, Bosinger S, Li J, Shah A Drug Metab Dispos. 2014; 42(12):2097-108.

PMID: 25301936 PMC: 4244873. DOI: 10.1124/dmd.114.059378.


Analysis of "Ecstasy" by capillary electrophoresis.

Frost M, Kohler H, Blaschke G Int J Legal Med. 1996; 109(2):53-7.

PMID: 8912047 DOI: 10.1007/BF01355516.