Direct Detector Radiography Versus Dual Reading Computed Radiography: Feasibility of Dose Reduction in Chest Radiography

Overview
Journal Eur Radiol
Specialty Radiology
Date 2006 Jan 13
PMID 16404566
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

The image quality of dual-reading computed radiography and dose-reduced direct radiography of the chest was compared in a clinical setting. The study group consisted of 50 patients that underwent three posteroanterior chest radiographs within minutes, one image obtained with a dual read-out computed radiography system (CR; Fuji 5501) at regular dose and two images with a flat panel direct detector unit (DR; Diagnost, Philips). The DR images were obtained with the same and with 50% of the dose used for the CR images. Images were evaluated in a blinded side-by-side comparison. Eight radiologists ranked the visually perceivable difference in image quality using a three-point scale. Then, three radiologists scored the visibility of anatomic landmarks in low and high attenuation areas and image noise. Statistical analysis was based on Friedman tests and Wilcoxon rank sum tests at a significance level of P<0.05. DR was judged superior to CR for the delineation of structures in high attenuation areas of the mediastinum even when obtained with 50% less dose (P<0.001). The visibility of most pulmonary structures was judged equivalent with both techniques, regardless of acquisition dose and speed level. Scores for image noise were lower for DR compared with CR, with the exception of DR obtained at a reduced dose. Thus, in this clinical preference study, DR was equivalent or even superior to the most modern dual read-out CR, even when obtained with 50% dose. A further dose reduction does not appear to be feasible for DR without significant loss of image quality.

Citing Articles

An Experimental Study for Minimum Level of Decalcification to Detect the Osteolytic Bone Metastasis of Long Bone on Plain Radiography.

Baek J, Park I, Seo S J Bone Metab. 2016; 23(3):135-42.

PMID: 27622177 PMC: 5018606. DOI: 10.11005/jbm.2016.23.3.135.


[Detection of lung nodules. New opportunities in chest radiography].

Potter-Lang S, Schalekamp S, Schaefer-Prokop C, Uffmann M Radiologe. 2014; 54(5):455-61.

PMID: 24789046 DOI: 10.1007/s00117-013-2599-x.


[Dose reduction and adequate image quality in digital radiography: a contradiction?].

Potter-Lang S, Dunkelmeyer M, Uffmann M Radiologe. 2012; 52(10):898-904.

PMID: 22986575 DOI: 10.1007/s00117-012-2337-9.


Assessment of patient doses in CR examinations throughout a large health region.

Thakur Y, Bjarnason T, Hammerstrom K, Marchinkow L, Koch T, Aldrich J J Digit Imaging. 2011; 25(1):189-95.

PMID: 21547516 PMC: 3264727. DOI: 10.1007/s10278-011-9390-1.


Detection of urinary stones at reduced radiation exposure: a phantom study comparing computed radiography and a low-dose digital radiography linear slit scanning system.

Szucs-Farkas Z, Chakraborty D, Thoeny H, Loupatatzis C, Vock P, Bonel H AJR Am J Roentgenol. 2009; 192(6):W271-4.

PMID: 19457787 PMC: 2826271. DOI: 10.2214/AJR.08.1502.


References
1.
Hosch W, Fink C, Radeleff B, kampschulte a A, Kauffmann G, Hansmann J . Radiation dose reduction in chest radiography using a flat-panel amorphous silicon detector. Clin Radiol. 2002; 57(10):902-7. DOI: 10.1053/crad.2002.0995. View

2.
Shaw C, Wang T, Breitenstein D, Gur D . Improvement of signal-to-noise and contrast-to-noise ratios in dual-screen computed radiography. Med Phys. 1997; 24(8):1293-302. DOI: 10.1118/1.598151. View

3.
Uffmann M, Prokop M, Eisenhuber E, Fuchsjager M, Weber M, Schaefer-Prokop C . Computed radiography and direct radiography: influence of acquisition dose on the detection of simulated lung lesions. Invest Radiol. 2005; 40(5):249-56. DOI: 10.1097/01.rli.0000159875.01324.bf. View

4.
Strotzer M, Volk M, Frund R, Hamer O, Zorger N, Feuerbach S . Routine chest radiography using a flat-panel detector: image quality at standard detector dose and 33% dose reduction. AJR Am J Roentgenol. 2002; 178(1):169-71. DOI: 10.2214/ajr.178.1.1780169. View

5.
Fink C, Hallscheidt P, Noeldge G, Kampschulte A, Radeleff B, Hosch W . Clinical comparative study with a large-area amorphous silicon flat-panel detector: image quality and visibility of anatomic structures on chest radiography. AJR Am J Roentgenol. 2002; 178(2):481-6. DOI: 10.2214/ajr.178.2.1780481. View