» Articles » PMID: 16315325

Nanoliter Scale Microbioreactor Array for Quantitative Cell Biology

Overview
Publisher Wiley
Specialty Biochemistry
Date 2005 Nov 30
PMID 16315325
Citations 36
Authors
Affiliations
Soon will be listed here.
Abstract

A nanoliter scale microbioreactor array was designed for multiplexed quantitative cell biology. An addressable 8 x 8 array of three nanoliter chambers was demonstrated for observing the serum response of HeLa human cancer cells in 64 parallel cultures. The individual culture unit was designed with a "C" shaped ring that effectively decoupled the central cell growth regions from the outer fluid transport channels. The chamber layout mimics physiological tissue conditions by implementing an outer channel for convective "blood" flow that feeds cells through diffusion into the low shear "interstitial" space. The 2 microm opening at the base of the "C" ring established a differential fluidic resistance up to 3 orders of magnitude greater than the fluid transport channel within a single mold microfluidic device. Three-dimensional (3D) finite element simulation were used to predict fluid transport properties based on chamber dimensions and verified experimentally. The microbioreactor array provided a continuous flow culture environment with a Peclet number (0.02) and shear stress (0.01 Pa) that approximated in vivo tissue conditions without limiting mass transport (10 s nutrient turnover). This microfluidic design overcomes the major problems encountered in multiplexing nanoliter culture environments by enabling uniform cell loading, eliminating shear, and pressure stresses on cultured cells, providing stable control of fluidic addressing, and permitting continuous on-chip optical monitoring.

Citing Articles

High-Throughput Methods in the Discovery and Study of Biomaterials and Materiobiology.

Yang L, Pijuan-Galito S, Rho H, Vasilevich A, Eren A, Ge L Chem Rev. 2021; 121(8):4561-4677.

PMID: 33705116 PMC: 8154331. DOI: 10.1021/acs.chemrev.0c00752.


Formation of cell spheroids using Standing Surface Acoustic Wave (SSAW).

Sriphutkiat Y, Kasetsirikul S, Zhou Y Int J Bioprint. 2020; 4(1):130.

PMID: 33102912 PMC: 7582004. DOI: 10.18063/IJB.v4i1.130.


Separating mouse malignant cell line (EL4) from neonate spermatogonial stem cells utilizing microfluidic device in vitro.

Ashtari B, Shams A, Esmaeilzadeh N, Tanbakooei S, Koruji M, Moghadam M Stem Cell Res Ther. 2020; 11(1):191.

PMID: 32448280 PMC: 7245899. DOI: 10.1186/s13287-020-01671-1.


A Single-Layer PDMS Chamber for On-Chip Bacteria Culture.

Morales Navarrete P, Yuan J Micromachines (Basel). 2020; 11(4).

PMID: 32290319 PMC: 7231344. DOI: 10.3390/mi11040395.


Liver Bioreactor Design Issues of Fluid Flow and Zonation, Fibrosis, and Mechanics: A Computational Perspective.

Rezania V, Coombe D, Tuszynski J J Funct Biomater. 2020; 11(1).

PMID: 32121053 PMC: 7151609. DOI: 10.3390/jfb11010013.