» Articles » PMID: 16287728

Multidetector Row Computed Tomography: Imaging Congenital Coronary Artery Anomalies in Adults

Overview
Journal Heart
Date 2005 Nov 17
PMID 16287728
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

The quality of the imaging of the main coronary arteries and side branches provided by multidetector row computed tomography (MDCT) may have importance when assessing congenital coronary artery anomalies. This review discusses the rationale for using MDCT for this indication and examines the advantages and disadvantages of the technique. Examples of MDCT imaging of congenital coronary artery anomalies are presented. These images provide persuasive evidence to support clinical use of MDCT cardiac imaging in the context of suspected congenital coronary artery anomalies as a first line investigation.

Citing Articles

A Pilot Study on the Role of Computed Tomography in the Management of Patients with Coronary Artery Anomalies in Romania.

Capisizu A, Cuzino D, Stanciu S J Cardiovasc Dev Dis. 2023; 10(4).

PMID: 37103049 PMC: 10142656. DOI: 10.3390/jcdd10040170.


Computed Tomography Imaging Findings of Acute Aortic Pathologies.

Duran E, Ahmad F, Elshikh M, Masood I, Duran C Cureus. 2019; 11(8):e5534.

PMID: 31687308 PMC: 6819069. DOI: 10.7759/cureus.5534.


Anomalous Origin of the Right Coronary Artery from the Left Main Coronary Artery in the Setting of Critical Bicuspid Aortic Valve Stenosis.

Singam N, Burkhart T, Ikram S Methodist Debakey Cardiovasc J. 2019; 15(3):223-225.

PMID: 31687103 PMC: 6822649. DOI: 10.14797/mdcj-15-3-223.


Anatomical variants and coronary anomalies detected by dual-source coronary computed tomography angiography in North-eastern Thailand.

Chaosuwannakit N Pol J Radiol. 2019; 83:e372-e378.

PMID: 30655913 PMC: 6334062. DOI: 10.5114/pjr.2018.78420.


A Case of Coronary Cameral Fistula with Associated Aneurysm: Role of ECG Gated 256- Slice Dual Source Multidetector Computed Tomography in Diagnosis.

Mittal U, Garg L, Rissam H, Puri S J Clin Diagn Res. 2016; 10(5):TD01-2.

PMID: 27437325 PMC: 4948501. DOI: 10.7860/JCDR/2016/18720.7797.


References
1.
Nieman K, Rensing B, van Geuns R, Vos J, Pattynama P, Krestin G . Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart. 2002; 88(5):470-4. PMC: 1767415. DOI: 10.1136/heart.88.5.470. View

2.
Nieman K, Cademartiri F, Lemos P, Raaijmakers R, Pattynama P, de Feyter P . Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation. 2002; 106(16):2051-4. DOI: 10.1161/01.cir.0000037222.58317.3d. View

3.
Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B . Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation. 2003; 107(5):664-6. DOI: 10.1161/01.cir.0000055738.31551.a9. View

4.
Morin R, Gerber T, McCollough C . Radiation dose in computed tomography of the heart. Circulation. 2003; 107(6):917-22. DOI: 10.1161/01.cir.0000048965.56529.c2. View

5.
Flohr T, Schoepf U, Kuettner A, Halliburton S, Bruder H, Suess C . Advances in cardiac imaging with 16-section CT systems. Acad Radiol. 2003; 10(4):386-401. DOI: 10.1016/s1076-6332(03)80027-2. View