Detection of Coronary Artery Stenoses with Thin-slice Multi-detector Row Spiral Computed Tomography and Multiplanar Reconstruction
Overview
Authors
Affiliations
Background: We analyzed the accuracy of multi-detector row spiral computed tomography (MDCT) using a 16-slice CT scanner with improved spatial and temporal resolution, as well as routine premedication with beta-blockers for detection of coronary stenoses.
Methods And Results: Seventy-seven patients with suspected coronary disease were studied by MDCT (12x0.75-mm cross-sections, 420 ms rotation, 100 mL contrast agent IV at 5 mL/s). Patients with a heart rate above 60/min received 50 mg atenolol before the scan. In axial MDCT images and multiplanar reconstructions, all coronary arteries and side branches with a diameter of 1.5 mm or more were assessed for the presence of stenoses exceeding 50% diameter reduction. In comparison to invasive coronary angiography, MDCT correctly classified 35 of 41 patients (85%) as having at least 1 coronary stenosis and correctly detected 57 of 78 coronary lesions (73%). After excluding 38 of 308 coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery in 77 patients) classified as unevaluable by MDCT (12%), 57 of 62 lesions were detected, and absence of stenosis was correctly identified in 194 of 208 arteries (sensitivity: 92%; specificity: 93%; accuracy: 93%; positive and negative predictive values: 79% and 97%).
Conclusions: MDCT coronary angiography with improved spatial resolution and premedication with oral beta-blockade permits detection of coronary artery stenoses with high accuracy and a low rate of unevaluable arteries.
Alhailiy A, Alkhybari E, Alshuhri M, Al-Othman A, Hegazi T, Alsuhaimi M Diagnostics (Basel). 2024; 14(14).
PMID: 39061660 PMC: 11275626. DOI: 10.3390/diagnostics14141523.
Park J, Kang E, Kim M, Yong H, Rha S PLoS One. 2022; 17(7):e0271189.
PMID: 35802711 PMC: 9269916. DOI: 10.1371/journal.pone.0271189.
Coronary artery aneurysm: A review.
Matta A, Yaacoub N, Nader V, Moussallem N, Carrie D, Roncalli J World J Cardiol. 2021; 13(9):446-455.
PMID: 34621489 PMC: 8462041. DOI: 10.4330/wjc.v13.i9.446.
CT Angiography or Cardiac MRI for Detection of Coronary Artery Aneurysms in Kawasaki Disease.
van Stijn D, Planken N, Kuipers I, Kuijpers T Front Pediatr. 2021; 9:630462.
PMID: 33614558 PMC: 7889592. DOI: 10.3389/fped.2021.630462.
A novel algorithm for refining cerebral vascular measurements in infants and adults.
Chen L, Dager S, Shaw D, Corrigan N, Mossa-Basha M, Pimentel K J Neurosci Methods. 2020; 340:108751.