Abstract

In this overview, the current status of intraocular lens surgery to correct refractive error is reviewed. The interventions are divided into additive surgery with intraocular lens implantation without extraction of the crystalline lens (phakic intraocular lens, PIOL) or removal of the crystalline lens with implantation of an IOL (refractive lens exchange, RLE). Phakic IOLs are constructed as angle-supported or iris-fixated anterior chamber lenses and posterior chamber lenses which are fixated in the ciliary sulcus. The implantation of phakic IOLs has been demonstrated to be an effective, safe, predictable and stable procedure to correct higher refractive errors. Complications are rare and differ for the three types of PIOL; for posterior chamber lenses these are mainly cataract formation and pigment dispersion. RLE is preferable in cases of high ametropia in which the natural lens has lost its accommodative effect. The main complications for myopic RLA include retinal detachment, while hyperopic refractive lens exchange may be associated with surgical problems in the narrower anterior eye segment.

Citing Articles

[Scheimpflug photography for the examination of phakic intraocular lenses].

Baumeister M Ophthalmologe. 2014; 111(10):935-41.

PMID: 25332044 DOI: 10.1007/s00347-013-2963-2.


Basic knowledge of refractive surgery: correction of refractive errors using modern surgical procedures.

Kohnen T, Strenger A, Klaproth O Dtsch Arztebl Int. 2009; 105(9):163-70.

PMID: 19633786 PMC: 2696744. DOI: 10.3238/arztebl.2008.0163.


Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using artemis VHF digital ultrasound.

Reinstein D, Archer T, Silverman R, Rondeau M, Coleman D J Refract Surg. 2009; 25(2):185-94.

PMID: 19241769 PMC: 2649749. DOI: 10.3928/1081597X-20090201-03.


[The basics of refractive lens exchange].

Kohnen T, Klaproth O Ophthalmologe. 2008; 105(11):991-2, 994-8.

PMID: 18998146 DOI: 10.1007/s00347-008-1827-7.


[Aspheric intraocular lenses].

Kohnen T, Klaproth O Ophthalmologe. 2008; 105(3):234-40.

PMID: 18311568 DOI: 10.1007/s00347-008-1718-y.


References
1.
Davidorf J, Zaldivar R, Oscherow S . Posterior chamber phakic intraocular lens for hyperopia of +4 to +11 diopters. J Refract Surg. 1998; 14(3):306-11. DOI: 10.3928/1081-597X-19980501-14. View

2.
Fechner P, Haubitz I, Wichmann W, Wulff K . Worst-Fechner biconcave minus power phakic iris-claw lens. J Refract Surg. 1999; 15(2):93-105. DOI: 10.3928/1081-597X-19990301-04. View

3.
Claoue C . Functional vision after cataract removal with multifocal and accommodating intraocular lens implantation: prospective comparative evaluation of Array multifocal and 1CU accommodating lenses. J Cataract Refract Surg. 2004; 30(10):2088-91. DOI: 10.1016/j.jcrs.2004.05.007. View

4.
Lyle W, Jin G . Clear lens extraction to correct hyperopia. J Cataract Refract Surg. 1997; 23(7):1051-6. DOI: 10.1016/s0886-3350(97)80079-x. View

5.
Barraquer C, Cavelier C, Mejia L . Incidence of retinal detachment following clear-lens extraction in myopic patients. Retrospective analysis. Arch Ophthalmol. 1994; 112(3):336-9. DOI: 10.1001/archopht.1994.01090150066025. View