» Articles » PMID: 16181815

Metabolic Fingerprinting of Rat Urine by LC/MS Part 1. Analysis by Hydrophilic Interaction Liquid Chromatography-electrospray Ionization Mass Spectrometry

Overview
Publisher Elsevier
Date 2005 Sep 27
PMID 16181815
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Complex biological samples, such as urine, contain a very large number of endogenous metabolites reflecting the metabolic state of an organism. Metabolite patterns can provide a comprehensive signature of the physiological state of an organism as well as insights into specific biochemical processes. Although the metabolites excreted in urine are commonly highly polar, the samples are generally analyzed using reversed-phase liquid chromatography mass spectrometry (RP-LC/MS). In Part 1 of this work, a method for detecting highly polar metabolites by hydrophilic interaction liquid chromatography-electrospray ionization mass spectrometry (HILIC/ESI-MS) is described as a complement to RP-LC/ESI-MS. In addition, in an accompanying paper (Part 2), different multivariate approaches to extracting information from the resulting complex data are described to enable metabolic fingerprints to be obtained. The coverage of the method for the screening of as many metabolites as possible is highly improved by analyzing the urine samples using both a C(18) column and a ZIC-HILIC column. The latter was found to be a good alternative when analyzing highly polar compounds, e.g., hydroxyproline and creatinine, to columns typically used for reversed-phase liquid chromatography.

Citing Articles

Systematic re-evaluation of the long-used standard protocol of urease-dependent metabolome sample preparation.

Kim J, Ahn J, Cheong Y, Lee S, Cha H, Kim K PLoS One. 2020; 15(3):e0230072.

PMID: 32182259 PMC: 7077817. DOI: 10.1371/journal.pone.0230072.


Metabolic profiling of femoral muscle from rats at different periods of time after death.

Du T, Lin Z, Xie Y, Ye X, Tu C, Jin K PLoS One. 2018; 13(9):e0203920.

PMID: 30216363 PMC: 6138414. DOI: 10.1371/journal.pone.0203920.


Retention and effective diffusion of model metabolites on porous graphitic carbon.

Lunn D, Yun Y, Jorgenson J J Chromatogr A. 2017; 1530:112-119.

PMID: 29157608 PMC: 5711574. DOI: 10.1016/j.chroma.2017.11.023.


Systems biology-opportunities and challenges: the application of proteomics to study the cardiovascular extracellular matrix.

Barallobre-Barreiro J, Lynch M, Yin X, Mayr M Cardiovasc Res. 2016; 112(3):626-636.

PMID: 27635058 PMC: 5157133. DOI: 10.1093/cvr/cvw206.


Optimized Analytical Procedures for the Untargeted Metabolomic Profiling of Human Urine and Plasma by Combining Hydrophilic Interaction (HILIC) and Reverse-Phase Liquid Chromatography (RPLC)-Mass Spectrometry.

Contrepois K, Jiang L, Snyder M Mol Cell Proteomics. 2015; 14(6):1684-95.

PMID: 25787789 PMC: 4458729. DOI: 10.1074/mcp.M114.046508.