Iterative RF Pulse Design for Multidimensional, Small-tip-angle Selective Excitation

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2005 Sep 13
PMID 16155881
Citations 38
Authors
Affiliations
Soon will be listed here.
Abstract

The excitation k-space perspective on small-tip-angle selective excitation has facilitated RF pulse designs in a range of MR applications. In this paper, k-space-based design of multidimensional RF pulses is formulated as a quadratic optimization problem, and solved efficiently by the iterative conjugate-gradient (CG) algorithm. Compared to conventional design approaches, such as the conjugate-phase (CP) method, the new design approach is beneficial in several regards. It generally produces more accurate excitation patterns. The improvement is particularly significant when k-space is undersampled, and it can potentially shorten pulse lengths. A prominent improvement in accuracy is also observed when large off-resonance gradients are present. A further boost in excitation accuracy can be accomplished in regions of interest (ROIs) if they are specified together with "don't-care" regions. The density compensation function (DCF) is no longer required. In addition, regularization techniques allow control over integrated and peak pulse power.

Citing Articles

Multidimensional RF pulse design with consideration of concomitant field effects.

Zhao Z, Lee N, Nayak K Magn Reson Med. 2024; 93(2):718-729.

PMID: 39365913 PMC: 11604853. DOI: 10.1002/mrm.30311.


Multiphoton parallel transmission (MP-pTx): Pulse design methods and numerical validation.

Drago J, Guerin B, Stockmann J, Wald L Magn Reson Med. 2024; 92(4):1376-1391.

PMID: 38899391 PMC: 11262987. DOI: 10.1002/mrm.30116.


Initial feasibility and challenges of hyperpolarized Xe MRI in neonates with bronchopulmonary dysplasia.

Stewart N, Higano N, Mukthapuram S, Willmering M, Loew W, West M Magn Reson Med. 2023; 90(6):2420-2431.

PMID: 37526031 PMC: 10629838. DOI: 10.1002/mrm.29808.


Selective RF excitation designs enabled by time-varying spatially non-linear ΔB fields with applications in fetal MRI.

Zhang M, Arango N, Stockmann J, White J, Adalsteinsson E Magn Reson Med. 2021; 87(5):2161-2177.

PMID: 34931714 PMC: 8847339. DOI: 10.1002/mrm.29114.


Joint Design of RF and Gradient Waveforms via Auto-differentiation for 3D Tailored Excitation in MRI.

Luo T, Noll D, Fessler J, Nielsen J IEEE Trans Med Imaging. 2021; 40(12):3305-3314.

PMID: 34029188 PMC: 8669750. DOI: 10.1109/TMI.2021.3083104.