» Articles » PMID: 16087093

Accuracy of Computed Tomography Attenuation Values in the Characterization of Pleural Fluid: an ROC Study

Overview
Journal Acad Radiol
Specialty Radiology
Date 2005 Aug 10
PMID 16087093
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Rationale And Objectives: To assess the accuracy of computed tomography (CT) in characterizing pleural fluid based on attenuation values.

Materials And Methods: Protocol was approved by the local institutional review board and informed consent was waived. We retrospectively analyzed 145 pleural effusions of 145 patients (mean/standard deviation age: 60.7/15.9 years; 69 females) who underwent CT of the thorax and diagnostic thoracentesis within 7 days of each other. Effusions were classified as transudates or exudates using laboratory markers based on Light's criteria. The mean Hounsfield units (HU) of an effusion was determined by a region of interest on the three slices with the greatest anteroposterior diameter. A receiver operating characteristic curve was constructed to determine threshold values for classification on the basis of mean HU and to examine overall accuracy, using the area under the curve (A(z)).

Results: Of the 101 exudates and 44 transudates, the mean attenuation of exudates (17.1 HU/standard deviation 4.4) was significantly higher than transudates (12.5 HU/6.3), (P < .001). There was a modest but significant positive relationship between mean HU and laboratory markers, with the strongest relationship with pleural/serum protein (r = 0.57, P < .001) and total pleural protein (r = 0.56, P < .001). The overall accuracy of attenuation values for identifying exudates was moderate, Az = 0.775, standard error = 0.039, with the largest limitation being the overlap with transudates in the 10-20 HU range, which constituted 66% (90/145) of the total effusions measured.

Conclusion: Although the mean attenuation of exudates is significantly higher than transudates, the clinical use of CT numbers to characterize pleural fluid is not recommended, as their accuracy is only moderate. Moreover, there is a notable overlap in attenuation values between transudates and exudates for a majority of effusions.

Citing Articles

Use of the Hounsfield unit scale in differentiating transudate and exudate in pleural effusion in the emergency department.

Isik N, Ozkan E, Ucgun A, Turan O, Donmez S, Yavuz Y Medicine (Baltimore). 2025; 104(10):e41822.

PMID: 40068056 PMC: 11902926. DOI: 10.1097/MD.0000000000041822.


Computed tomography attenuation in differential diagnosis of transudative and exudative pleural effusions.

Gumus A, Ozcelik N, Yilmaz Kara B, Hursoy N, Zirih N, Ozyurt S Clinics (Sao Paulo). 2024; 79:100463.

PMID: 39111190 PMC: 11347058. DOI: 10.1016/j.clinsp.2024.100463.


The mean Hounsfield unit range acquired from different slices produces superior predictive accuracy for pyonephrosis in obstructive uropathy.

Huang B, Lu G, Zhao Y, Tu W, Shao Y, Wang D Investig Clin Urol. 2024; 65(3):286-292.

PMID: 38714519 PMC: 11076793. DOI: 10.4111/icu.20230240.


Diagnostic accuracy of thoracic CT to differentiate transudative from exudative pleural effusion prior to thoracentesis.

Zhang Y, Zhang Y, Wang W, Feng X, Guo J, Chen B Respir Res. 2024; 25(1):53.

PMID: 38263145 PMC: 10807107. DOI: 10.1186/s12931-024-02681-w.


Can diffusion-weighted imaging be used in the examination of peritoneal fluids?.

Keskin Z Pol J Radiol. 2023; 88:e149-e154.

PMID: 37057204 PMC: 10086605. DOI: 10.5114/pjr.2023.126135.