The Continuous Glucose Monitoring Sensor in Neonatal Intensive Care

Overview
Date 2005 Jul 23
PMID 16036889
Citations 37
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To determine the feasibility of continuous glucose monitoring in the very low birthweight baby requiring intensive care, as these infants are known to be at high risk of abnormalities of glucose control.

Method: Sixteen babies were studied from within 24 hours of delivery and for up to seven days.

Results: The subcutaneous glucose sensors were well tolerated and readings were comparable to those on near patient whole blood monitoring devices.

Conclusion: Continuous glucose monitoring is practical in neonates, giving detailed information about glucose control.

Citing Articles

Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review.

Nielsen C, Grigonyte-Daraskeviciene M, Olsen M, Moller M, Norgaard K, Perner A Intensive Care Med. 2024; 50(12):2005-2018.

PMID: 39417874 DOI: 10.1007/s00134-024-07663-6.


Treatment of Severe Hyperglycemia in Extremely Preterm Infants Using Continuous Subcutaneous Insulin Therapy.

Boettger M, Zhou T, Knopp J, Chase J, Heep A, von Vangerow M J Clin Res Pediatr Endocrinol. 2024; 16(4):443-449.

PMID: 38915194 PMC: 11629728. DOI: 10.4274/jcrpe.galenos.2024.2024-2-9.


A Higher Amount of Nutritional Intake as a Possible Cause of Hyperglycemia in Extremely Premature Infants in Parenteral and Enteral Nutrition at the Tertiary Neonatal Intensive Care Unit.

Predanic Drobne I, Kornhauser Cerar L, Erculj V, Grosek S Children (Basel). 2023; 10(10).

PMID: 37892314 PMC: 10605466. DOI: 10.3390/children10101651.


Continuous Glucose Monitoring in Transient Neonatal Diabetes Mellitus-2 Case Reports and Literature Review.

Chisnoiu T, Balasa A, Mihai L, Lupu A, Frecus C, Ion I Diagnostics (Basel). 2023; 13(13).

PMID: 37443665 PMC: 10340365. DOI: 10.3390/diagnostics13132271.


Should continuous glucose monitoring be used to manage neonates at risk of hypoglycaemia?.

Kalogeropoulou M, Iglesias-Platas I, Beardsall K Front Pediatr. 2023; 11:1115228.

PMID: 37025284 PMC: 10070986. DOI: 10.3389/fped.2023.1115228.


References
1.
Cornblath M, Hawdon J, Williams A, Aynsley-Green A, Ward-Platt M, Schwartz R . Controversies regarding definition of neonatal hypoglycemia: suggested operational thresholds. Pediatrics. 2000; 105(5):1141-5. DOI: 10.1542/peds.105.5.1141. View

2.
Gross T, Bode B, Einhorn D, Kayne D, Reed J, White N . Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diabetes Technol Ther. 2001; 2(1):49-56. DOI: 10.1089/152091500316737. View

3.
Amin R, Ross K, Acerini C, Edge J, Warner J, Dunger D . Hypoglycemia prevalence in prepubertal children with type 1 diabetes on standard insulin regimen: use of continuous glucose monitoring system. Diabetes Care. 2003; 26(3):662-7. DOI: 10.2337/diacare.26.3.662. View

4.
FINBERG L . Dangers to infants caused by changes in osmolal concentration. Pediatrics. 1967; 40(6):1031-4. View

5.
Rebrin K, Steil G, van Antwerp W, Mastrototaro J . Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. Am J Physiol. 1999; 277(3):E561-71. DOI: 10.1152/ajpendo.1999.277.3.E561. View