» Articles » PMID: 15958173

Quantification of Resting Myocardial Blood Flow Velocity in Normal Humans Using Real-time Contrast Echocardiography. A Feasibility Study

Overview
Publisher Biomed Central
Date 2005 Jun 17
PMID 15958173
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Real-time myocardial contrast echocardiography (MCE) is a novel method for assessing myocardial perfusion. The aim of this study was to evaluate the feasibility of a very low-power real-time MCE for quantification of regional resting myocardial blood flow (MBF) velocity in normal human myocardium.

Methods: Twenty study subjects with normal left ventricular (LV) wall motion and normal coronary arteries, underwent low-power real-time MCE based on color-coded pulse inversion Doppler. Standard apical LV views were acquired during constant IV. infusion of SonoVue. Following transient microbubble destruction, the contrast replenishment rate (beta), reflecting MBF velocity, was derived by plotting signal intensity vs. time and fitting data to the exponential function; y (t) =A (1-e(-beta(t-t0))) + C.

Results: Quantification was feasible in 82%, 49% and 63% of four-chamber, two-chamber and apical long-axis view segments, respectively. The LAD (left anterior descending artery) and RCA (right coronary artery) territories could potentially be evaluated in most, but contrast detection in the LCx (left circumflex artery) bed was poor. Depending on localisation and which frames to be analysed, mean values of beta were 0.21-0.69 s(-1), with higher values in medial than lateral, and in basal compared to apical regions of scan plane (p = 0.03 and p < 0.01). Higher beta-values were obtained from end-diastole than end-systole (p < 0.001), values from all-frames analysis lying between.

Conclusion: Low-power real-time MCE did have the potential to give contrast enhancement for quantification of resting regional MBF velocity. However, the technique is difficult and subjected to several limitations. Significant variability in beta suggests that this parameter is best suited for with-in patient changes, comparing values of stress studies to baseline.

Citing Articles

Feasibility of myocardial perfusion assessment with contrast echocardiography: can it improve recognition of significant coronary artery disease in the ICU?.

Orde S, Slama M, Pathan F, Huang S, McLean A Crit Care. 2019; 23(1):257.

PMID: 31315648 PMC: 6635996. DOI: 10.1186/s13054-019-2519-1.


Optimisation of ultrasound liver perfusion through a digital reference object and analysis tool.

Alberich-Bayarri A, Tomas-Cucarella J, Torregrosa-Lloret A, Saiz Rodriguez J, Marti-Bonmati L Eur Radiol Exp. 2019; 3(1):15.

PMID: 30945029 PMC: 6447630. DOI: 10.1186/s41747-019-0086-5.


Myocardial contrast echocardiography for the detection of coronary artery disease in patients with global hypokinesis admitted for first-onset acute heart failure: pilot study.

Kim S, Park D, Hong J, Lee J, Han K, Oh D J Cardiovasc Ultrasound. 2014; 22(3):121-6.

PMID: 25309688 PMC: 4192409. DOI: 10.4250/jcu.2014.22.3.121.


Quantitative analysis of myocardial perfusion in rabbits by transthoracic real-time myocardial contrast echocardiography.

Deng H, Xie M, Wang X, Lv Q, Li S, Bao Y J Huazhong Univ Sci Technolog Med Sci. 2009; 29(6):795-9.

PMID: 20037830 DOI: 10.1007/s11596-009-0625-z.

References
1.
Schiller N, Shah P, Crawford M, DeMaria A, Devereux R, FEIGENBAUM H . Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr. 1989; 2(5):358-67. DOI: 10.1016/s0894-7317(89)80014-8. View

2.
Leistad E, Ohmori K, Peterson T, Christensen G, DeMaria A . Quantitative assessment of myocardial perfusion during graded coronary artery stenoses by intravenous myocardial contrast echocardiography. J Am Coll Cardiol. 2001; 37(2):624-31. DOI: 10.1016/s0735-1097(00)01127-x. View

3.
Wei K, Jayaweera A, Firoozan S, Linka A, Skyba D, Kaul S . Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation. 1998; 97(5):473-83. DOI: 10.1161/01.cir.97.5.473. View

4.
Heinle S, Noblin J, Mello A, Ravad G, Mull S, Mammen P . Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress: comparison with (99m)Tc-sestamibi SPECT imaging. Circulation. 2000; 102(1):55-60. DOI: 10.1161/01.cir.102.1.55. View

5.
Villanueva F, Gertz E, Csikari M, Pulido G, Fisher D, Sklenar J . Detection of coronary artery stenosis with power Doppler imaging. Circulation. 2001; 103(21):2624-30. DOI: 10.1161/01.cir.103.21.2624. View