» Articles » PMID: 15907877

Cytotoxicity Test Based on Electrochemical Impedance Measurement of HepG2 Cultured in Microfabricated Cell Chip

Overview
Journal Anal Biochem
Publisher Elsevier
Specialty Biochemistry
Date 2005 May 24
PMID 15907877
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

This paper presents the use of electrochemical impedance measurement on a cell chip to monitor cell growth as a consequence of treatment with potentially cytotoxic agents. The cell chip consists of an eight-well cell culture chamber incorporated with a three-electrode system on each well. The gold electrode for impedance measurements is fabricated by sputtering on polycarbonate film. Human hepatocellular carcinoma cell (HepG2) is adapted to cytotoxicity test using the cell chip. Although the relatively small quantity of cells on the electrode has been measured indirectly, the cell chip can monitor toxic effects on the HepG2 cells cultured in the cell chip continuously and detect cellular behavior without multiple reagents. The cells in the stationary phase after plating are used for the cytotoxicity experiment and the impedance is decreased after treatments with several toxicants, such as tamoxifen and menadione, indicating the detachment of dead cells. These results reveal that the microfabricated cell chip system provides an easy and real-time monitoring method for cytotoxicity test.

Citing Articles

Development of a Flexible Sensor-Integrated Tissue Patch to Monitor Early Organ Rejection Processes Using Impedance Spectroscopy.

Ertl P, Wladimir T, Sticker D, Schuller P, Rothbauer M, Wieselthaler G Biosensors (Basel). 2024; 14(5).

PMID: 38785727 PMC: 11118035. DOI: 10.3390/bios14050253.


Four electrode-based impedimetric biosensors for evaluating cytotoxicity of tamoxifen on cervical cancer cells.

Pradhan R, Kalkal A, Jindal S, Packirisamy G, Manhas S RSC Adv. 2022; 11(2):798-806.

PMID: 35423705 PMC: 8693377. DOI: 10.1039/d0ra09155c.


Electrochemical Biosensors Based on S-Layer Proteins.

Damiati S, Schuster B Sensors (Basel). 2020; 20(6).

PMID: 32204503 PMC: 7147708. DOI: 10.3390/s20061721.


Integration Method of Microchannel and Vertical Micromesh Structure for Three-Dimensional Cell Culture Using Inclined Exposure and Inclined Oxygen Ashing.

Ueno H, Yamada K, Suzuki T Micromachines (Basel). 2018; 9(12).

PMID: 30572685 PMC: 6316158. DOI: 10.3390/mi9120681.


Nanostructured surfaces for analysis of anticancer drug and cell diagnosis based on electrochemical and SERS tools.

El-Said W, Yoon J, Choi J Nano Converg. 2018; 5(1):11.

PMID: 29721403 PMC: 5913382. DOI: 10.1186/s40580-018-0143-4.