Abstract

Purpose: To prospectively determine whether combined positron emission tomography (PET) and computed tomography (CT) is more accurate than either PET or CT alone in depicting malignant lesions in the head and neck.

Materials And Methods: Study was approved by the institutional review board, and patient informed consent was waived. Sixty-five consecutive patients (42 men, 23 women; age range, 43-83 years) known to have or suspected of having head and neck cancer were examined with combined PET/CT. CT was performed with intravenous administration of a contrast agent, and the CT data were used for attenuation correction. Each examination was interpreted in three ways: PET images in the absence of CT data, CT images in the absence of PET data, and fused PET/CT images. Probability of malignancy of each lesion was assigned a score by using a five-point scale. Receiver operating characteristic (ROC) analyses were performed by using biopsy, imaging, or clinical follow-up as the reference standard. The minimum follow-up was 6 months (range, 6-12 months). The results were additionally analyzed to assess the degree of radiologist confidence.

Results: Follow-up was available for 64 (98%) of 65 patients. ROC analyses demonstrated that PET/CT is significantly superior to PET or CT alone for depiction of malignancy in the head and neck (P < .05). In this series, PET/CT had a sensitivity of 98%, a specificity of 92%, and an accuracy of 94%. Radiologist confidence was substantially higher with the combined modality.

Conclusion: Combined PET/CT is more accurate than PET or CT alone for the depiction of malignancy in the head and neck. Radiologist confidence is improved with the combined modality.

Citing Articles

Comparisons of 3D printed materials for biomedical imaging applications.

Gabalski M, Smith K, Hix J, Zinn K Sci Technol Adv Mater. 2024; 24(1):2273803.

PMID: 38415266 PMC: 10898812. DOI: 10.1080/14686996.2023.2273803.


Correlation between PET-CT and ct in the staging after the treatment of head and neck squamous cell carcinoma.

Garcia-Curdi F, Lois-Ortega Y, Muniesa-Del Campo A, McGee-Laso A, Sebastian-Cortes J, Valles-Varela H Braz J Otorhinolaryngol. 2021; 88 Suppl 4:S143-S151.

PMID: 34933818 PMC: 9756050. DOI: 10.1016/j.bjorl.2021.11.008.


Primary Intramedullary Spinal Melanoma: A Rare Disease of the Spinal Cord.

Zahra F, Ajmal Z, Qian J, Wrzesinski S Cureus. 2021; 13(7):e16194.

PMID: 34367798 PMC: 8336382. DOI: 10.7759/cureus.16194.


Automatic Segmentation of Mandible from Conventional Methods to Deep Learning-A Review.

Qiu B, van der Wel H, Kraeima J, Glas H, Guo J, Borra R J Pers Med. 2021; 11(7).

PMID: 34357096 PMC: 8307673. DOI: 10.3390/jpm11070629.


Diagnostic Accuracy and Confidence of [18F] FDG PET/MRI in comparison with PET or MRI alone in Head and Neck Cancer.

Park J, Pak K, Yun T, Lee E, Ryoo I, Lee J Sci Rep. 2020; 10(1):9490.

PMID: 32528161 PMC: 7289810. DOI: 10.1038/s41598-020-66506-8.