Comparison of Autotriggered Memory Loop Recorders Versus Standard Loop Recorders Versus 24-hour Holter Monitors for Arrhythmia Detection

Overview
Journal Am J Cardiol
Date 2005 Apr 22
PMID 15842970
Citations 23
Authors
Affiliations
Soon will be listed here.
Abstract

To determine the relative yields of Holter monitoring (HM), memory loop recording (MLR), and autotriggered MLR (AT-MLR), we retrospectively interrogated the very large database of Lifewatch (a Card Guard company and a commercial monitoring company) and compared the results obtained by each method. From among a total database of approximately 100,000 patients, records of 1,800 patients from 2003 were randomly selected and examined, 600 from each of the 3 different monitoring groups. Each session of MLR and AT-MLR was applied for 30 days. For each patient we determined the symptomatic and asymptomatic events that were documented, including those that met predefined immediate physician notification criteria and the time to first notification event. The groups were identical in age and symptoms that necessitated monitoring; fewer women had HM. Information on the type of underlying structural heart disease, if present, and medications taken, if any, was not available to us in this database. The AT-MLR approach provided a higher yield of diagnostic events (e.g., 37, 108, and 216 total patients who had events; 37, 212, and 524 total events; and 6.2%, 17%, and 36% with a diagnostic yield for HM, MLR, and AT-MLR, respectively) and an earlier diagnosis. AT-MLR was also the most effective technique for capturing asymptomatic significant events, such as atrial fibrillation (52 with AT-MLR vs 1 for standard MLR). AT-MLR detected more than half as many asymptomatic episodes of atrial fibrillation (n = 52) as the total number of symptomatic episodes detected by patient activated recording (n = 94), thus confirming the common presence of asymptomatic atrial fibrillation. AT-MLR provided electrocardiographic documentation of tachyarrhythmias (n = 392) more often than MLR (n = 47) or HM (n = 44) and bradyarrhythmias/pauses/atrioventricular block (n = 38) more often than MLR (n = 13) or HM (n = 18). Thus, MLR and AT-MLR provide a diagnosis more often than does HM, thus confirming the benefit of prolonged monitoring. Further, the higher yield of AT-MLR versus MLR demonstrates the significantly enhanced benefit of autotriggered programmable recording.

Citing Articles

Use of a smartphone electrocardiogram to diagnose arrhythmias during exercise in athletes: a case series.

Jewson J, Orchard J, Semsarian C, Fitzpatrick J, La Gerche A, Orchard J Eur Heart J Case Rep. 2022; 6(4):ytac126.

PMID: 35434508 PMC: 9007431. DOI: 10.1093/ehjcr/ytac126.


Remote and wearable ECG devices with diagnostic abilities in adults: A state-of-the-science scoping review.

Bouzid Z, Al-Zaiti S, Bond R, Sejdic E Heart Rhythm. 2022; 19(7):1192-1201.

PMID: 35276320 PMC: 9250606. DOI: 10.1016/j.hrthm.2022.02.030.


A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring.

Shen Q, Li J, Cui C, Wang X, Gao H, Liu C J Biomed Res. 2021; 35(3):238-246.

PMID: 33495426 PMC: 8193711. DOI: 10.7555/JBR.34.20200074.


Cardiac Ambulatory Monitoring: New Wireless Device Validated Against Conventional Holter Monitoring in a Case Series.

Murali S, Brugger N, Rincon F, Mashru M, Cook S, Goy J Front Cardiovasc Med. 2020; 7:587945.

PMID: 33330650 PMC: 7733961. DOI: 10.3389/fcvm.2020.587945.


When Silence Isn't Golden: The Case of "Silent" Atrial Fibrillation.

Reiffel J J Innov Card Rhythm Manag. 2020; 8(11):2886-2893.

PMID: 32477759 PMC: 7252797. DOI: 10.19102/icrm.2017.081102.