Comparison of Inhomogeneity Correction Algorithms in Small Photon Fields

Overview
Journal Med Phys
Specialty Biophysics
Date 2005 Apr 21
PMID 15839349
Citations 36
Authors
Affiliations
Soon will be listed here.
Abstract

Algorithms such as convolution superposition, Batho, and equivalent pathlength which were originally developed and validated for conventional treatments under conditions of electronic equilibrium using relatively large fields greater than 5 x 5 cm2 are routinely employed for inhomogeneity corrections. Modern day treatments using intensity modulated radiation therapy employ small beamlets characterized by the resolution of the multileaf collimator. These beamlets, in general, do not provide electronic equilibrium even in a homogeneous medium, and these effects are exaggerated in media with inhomogenieties. Monte Carlo simulations are becoming a tool of choice in understanding the dosimetry of small photon fields as they encounter low density media. In this study, depth dose data from the Monte Carlo simulations are compared to the results of the convolution superposition, Batho, and equivalent pathlength algorithms. The central axis dose within the low-density inhomogeneity as calculated by Monte Carlo simulation and convolution superposition decreases for small field sizes whereas it increases using the Batho and equivalent pathlength algorithms. The dose perturbation factor (DPF) is defined as the ratio of dose to a point within the inhomogeneity to the same point in a homogeneous phantom. The dose correction factor is defined as the ratio of dose calculated by an algorithm at a point to the Monte Carlo derived dose at the same point, respectively. DPF is noted to be significant for small fields and low density for all algorithms. Comparisons of the algorithms with Monte Carlo simulations is reflected in the DCF, which is close to 1.0 for the convolution-superposition algorithm. The Batho and equivalent pathlength algorithms differ significantly from Monte Carlo simulation for most field sizes and densities. Convolution superposition shows better agreement with Monte Carlo data versus the Batho or equivalent pathlength corrections. As the field size increases the DCF's for all algorithms converge toward 1.0. The largest differences in DCF are at the interface where changes in electron transport are greatest. For a 6 MV photon beam, electronic equilibrium is restored at field sizes above 3 cm diameter and all of the algorithms predict dose in and beyond the inhomogeneous region equally well. For accurate dosimetry of small fields within and near inhomogeneities, however, simple algorithms such as Batho and equivalent pathlength should be avoided.

Citing Articles

Comparative assessment and QA measurement array validation of Monte Carlo and Collapsed Cone dose algorithms for small fields and clinical treatment plans.

Spenkelink G, Huijskens S, Zindler J, de Goede M, van der Star W, van Egmond J J Appl Clin Med Phys. 2024; 25(12):e14522.

PMID: 39287551 PMC: 11633799. DOI: 10.1002/acm2.14522.


Clinical application of a GPU-accelerated monte carlo dose verification for cyberknife M6 with Iris collimator.

Zhou P, Chang Y, Li S, Luo J, Lei L, Shang Y Radiat Oncol. 2024; 19(1):86.

PMID: 38956685 PMC: 11221037. DOI: 10.1186/s13014-024-02446-1.


Dosimetric Evaluation of Radiation Treatment Planning for Simultaneous Integrated Boost Technique Using Monte Carlo Simulation.

Shende R, Dhoble S, Gupta G J Med Phys. 2023; 48(3):298-306.

PMID: 37969148 PMC: 10642595. DOI: 10.4103/jmp.jmp_4_23.


Variability of Low-Z Inhomogeneity Correction in IMRT/SBRT: A Multi-Institutional Collaborative Study.

Yadav P, DesRosiers C, Mitra R, Srivastava S, Das I J Clin Med. 2023; 12(3).

PMID: 36769553 PMC: 9918128. DOI: 10.3390/jcm12030906.


The Effect of Algorithms on Dose Distribution in Inhomogeneous Phantom: Monaco Treatment Planning System versus Monte Carlo Simulation.

Tugrul T J Med Phys. 2021; 46(2):111-115.

PMID: 34566291 PMC: 8415246. DOI: 10.4103/jmp.JMP_21_21.