» Articles » PMID: 15834910

Method for Improving the Accuracy of Quantitative Cerebral Perfusion Imaging

Overview
Date 2005 Apr 19
PMID 15834910
Citations 27
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To improve the accuracy of dynamic susceptibility contrast (DSC) measurements of cerebral blood flow (CBF) and volume (CBV).

Materials And Methods: In eight volunteers, steady-state CBV (CBV(SS)) was measured using TrueFISP readout of inversion recovery (IR) before and after injection of a bolus of contrast. A standard DSC (STD) perfusion measurement was performed by echo-planar imaging (EPI) during passage of the bolus and subsequently used to calculate the CBF (CBF(DSC)) and CBV (CBV(DSC)). The ratio of CBV(SS) to CBV(DSC) was used to calibrate measurements of CBV and CBF on a subject-by-subject basis.

Results: Agreement of values of CBV (1.77 +/- 0.27 mL/100 g in white matter (WM), 3.65 +/- 1.04 mL/100 g in gray matter (GM)), and CBF (23.6 +/- 2.4 mL/(100 g min) in WM, 57.3 +/- 18.2 mL/(100 g min) in GM) with published gold-standard values shows improvement after calibration. An F-test comparison of the coefficients of variation of the CBV and CBF showed a significant reduction, with calibration, of the variability of CBV in WM (P < 0.001) and GM (P < 0.03), and of CBF in WM (P < 0.0001).

Conclusion: The addition of a CBV(SS) measurement to an STD measurement of cerebral perfusion improves the accuracy of CBV and CBF measurements. The method may prove useful for assessing patients suffering from acute stroke.

Citing Articles

Quantification of Collateral Supply with Local-AIF Dynamic Susceptibility Contrast MRI Predicts Infarct Growth.

Liu M, Saadat N, Roth S, Niekrasz M, Giurcanu M, Carroll T AJNR Am J Neuroradiol. 2024; 46(2):251-258.

PMID: 39134367 PMC: 11878984. DOI: 10.3174/ajnr.A8441.


Quantification of Collateral Supply with Local-AIF Dynamic Susceptibility Contrast MRI Predicts Infarct Growth.

Liu M, Saadat N, Roth S, Niekrasz M, Giurcanu M, Carroll T ArXiv. 2024; .

PMID: 38883243 PMC: 11177949.


Evaluation of infarct core and ischemic penumbra by absolute quantitative cerebral dynamic susceptibility contrast perfusion magnetic resonance imaging using self-calibrated echo planar imaging sequencing in patients with acute ischemic stroke.

Ma X, Wang Y, Wang M, Zhang M, Meng N, Zhang L Quant Imaging Med Surg. 2022; 12(8):4286-4295.

PMID: 35919056 PMC: 9338368. DOI: 10.21037/qims-21-975.


Longitudinal structural and perfusion MRI enhanced by machine learning outperforms standalone modalities and radiological expertise in high-grade glioma surveillance.

Siakallis L, Sudre C, Mulholland P, Fersht N, Rees J, Topff L Neuroradiology. 2021; 63(12):2047-2056.

PMID: 34047805 PMC: 8589799. DOI: 10.1007/s00234-021-02719-6.


Absolute quantitative MR perfusion and comparison against stable-isotope microspheres.

Jeong Y, Christoforidis G, Saadat N, Kawaji K, Cantrell C, Roth S Magn Reson Med. 2019; 81(6):3567-3577.

PMID: 30737833 PMC: 6435411. DOI: 10.1002/mrm.27669.