Visualization of Fluid Turbulence and Acoustic Cavitation During Phacoemulsification

Overview
Specialty Ophthalmology
Date 2005 Mar 16
PMID 15767166
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To describe a technique for visualizing fluid turbulence and cavitational energy created by ultrasonic phaco tips.

Setting: University Eye Clinic of Trieste, Trieste, Italy.

Methods: Generation of cavitational energy by the phaco tip was visualized using an optical test bench comprising several components. The technique uses a telescope system to expand a laser light source into a coherent, collimated beam of light with a diameter of approximately 50.0 mm. The expanded laser beam shines on the test tube containing the tip activated in a medium of water or ophthalmic viscosurgical device (OVD). Two precision optical collimators complete the optical test bench and form the system used to focus data onto a charge-coupled device television camera connected to a recorder.

Results: Images of irrigation, irrigation combined with aspiration, irrigation/aspiration, and phacosonication were obtained with the tip immersed in a tube containing water or OVD.

Conclusions: Optical image processing enabled acoustic cavitation to be visualized during phacosonication. The system is a possible means of evaluating a single phaco apparatus power setting and comparing phaco machines and techniques.

Citing Articles

Simulation of fluid dynamics and turbulence during phacoemulsification using the new propeller turbo tip.

Wang X, Wang X BMJ Open Ophthalmol. 2023; 8(1).

PMID: 37775137 PMC: 10546181. DOI: 10.1136/bmjophth-2023-001391.


In vitro analysis of clinically relevant aspects of a polymer-coated phacoemulsification tip vs a traditional tip.

Zacharias J J Cataract Refract Surg. 2023; 49(12):1264-1269.

PMID: 37464557 PMC: 10664810. DOI: 10.1097/j.jcrs.0000000000001267.


Comparison of 45-degree Kelman and 45-degree balanced phaco tip designs in torsional microcoaxial phacoemulsification.

Demircan S, Atas M, Goktas E, Baskan B Int J Ophthalmol. 2015; 8(6):1168-72.

PMID: 26682167 PMC: 4651883. DOI: 10.3980/j.issn.2222-3959.2015.06.16.


Visualization of irrigation fluid flow and calculation of its velocity distribution in the anterior chamber by particle image velocimetry.

Kaji Y, Yamashita M, Sakakibara J, Oshika T Graefes Arch Clin Exp Ophthalmol. 2012; 250(7):1023-7.

PMID: 22350059 DOI: 10.1007/s00417-012-1953-4.