Six Years' Experience of Using the BacT/ALERT System to Screen All Platelet Concentrates, and Additional Testing of Outdated Platelet Concentrates to Estimate the Frequency of False-negative Results

Overview
Journal Vox Sang
Specialty Hematology
Date 2005 Feb 22
PMID 15720606
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Objectives: Approximately 1 in every 2000 units of platelets is contaminated with bacteria. The BacT/ALERT automated blood culture system can be used to screen platelet concentrates (PCs) for bacterial contamination.

Materials And Methods: Data were collected from May 1998 until May 2004. The number of PCs tested during this period was 36 896, most of which were produced from pools of four buffy-coats. On the day following blood collection or platelet apheresis, a 5-10 ml sample of the PC was aseptically transferred to a BacT/ALERT culture bottle for detection of aerobic bacteria. The sample was monitored for bacterial growth during the entire storage period of the PC (6.5 days). When a positive signal was generated, the culture bottle, the PC and the erythrocyte concentrates were tested for bacterial growth. In order to determine the frequency of false-negative BacT/ALERT signals, 1061 outdated PCs were tested during the period from May 2002 to May 2004.

Results: Eighty-eight positive signals were detected by the BacT/ALERT system, of which 12 were interpreted as truly positive. Fourteen signals were interpreted as truly false positive. Thirty-three signals were interpreted to be probably false positive. Two of 1061 outdated units tested positive, and Bacillus spp. and Staphylococcus epidermidis, respectively, were isolated from these PCs.

Conclusions: Between 0.03% and 0.12% of the PCs were contaminated with bacteria. BacT/ALERT is an efficient tool for monitoring PCs for bacterial contamination; however, it is important to realize that false-negative results may occur.

Citing Articles

Secondary bacterial culture of platelets to mitigate transfusion-associated sepsis: A 3-year analysis at a large academic institution.

Fenwick A, Gehrie E, Marshall C, Tobian A, Shrestha R, Kacker S Transfusion. 2020; 60(9):2021-2028.

PMID: 32750171 PMC: 10007897. DOI: 10.1111/trf.15978.


Blood utilisation and transfusion reactions in adult patients transfused with conventional or pathogen-reduced platelets.

Bahar B, Schulz W, Gokhale A, Spencer B, Gehrie E, Snyder E Br J Haematol. 2019; 188(3):465-472.

PMID: 31566724 PMC: 7003815. DOI: 10.1111/bjh.16187.


Transfusion-Transmitted Infections Reported to the National Healthcare Safety Network Hemovigilance Module.

Haass K, Sapiano M, Savinkina A, Kuehnert M, Basavaraju S Transfus Med Rev. 2019; 33(2):84-91.

PMID: 30930009 PMC: 6520165. DOI: 10.1016/j.tmrv.2019.01.001.


Evaluation of Mirasol pathogen reduction system by artificially contaminating platelet concentrates with Staphylococcus epidermidis: A pilot study from India.

Chatterjee K, Zaman S, Chaurasia R, Singh S, Keil S, Tewari S Asian J Transfus Sci. 2016; 10(2):127-31.

PMID: 27605849 PMC: 4993081. DOI: 10.4103/0973-6247.187946.


INVESTIGATION OF BIOFILM FORMATION IN COAGULASE-NEGATIVE STAPHYLOCOCCI ISOLATED FROM PLATELET CONCENTRATE BAGS.

Martini R, Horner R, Rampelotto R, Garzon L, Nunes M, Dalcin Teixeira M Rev Inst Med Trop Sao Paulo. 2016; 58:1.

PMID: 26910444 PMC: 4793942. DOI: 10.1590/S1678-9946201658001.