» Articles » PMID: 15693085

Detection of Erosions in the Rheumatoid Hand; a Comparative Study of Multidetector Computerized Tomography Versus Magnetic Resonance Scanning

Overview
Journal J Rheumatol
Specialty Rheumatology
Date 2005 Feb 5
PMID 15693085
Citations 37
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To compare the detection and scoring of erosions in patients with rheumatoid arthritis (RA) using magnetic resonance (MR) and multidetector helical computerized tomographic (CT) scanning.

Methods: Comparative CT and MR scans of the dominant wrist were obtained from 9 patients with RA and clinical examination was performed to assess disease activity. MR and CT scans were scored for erosions and MR scans for bone edema by 2 radiologists using a validated system. Radiographs of the hands and feet were also scored for erosions using the modified Sharp score.

Results: In 117 of 135 (87%) sites there was concordance for erosions between MR and CT scans. At the remaining 18/135 sites (13%), erosions were identified by CT but not MR in 12/135 (9%) and by MR but not CT in 6/135 (4%). Partial volume artefacts on MR images and shifts in slice position were the most common reasons for erosion mismatch between MR and CT. The mean CT bone erosion score was significantly higher than the MR erosion score when individual bony sites were examined (p = 0.024), with the greatest difference being at the metacarpal bases. The total bone erosion score also tended to be higher on CT than MR [median scores of 20 (range 0-66) and 12 (0-51), respectively; p = 0.060]. MR and CT erosion scores correlated strongly with the total Sharp score (r = 0.93, p = 0.0002 and r = 0.94, p = 0.0002, respectively) and with the Disease Activity Score (MR: r = 0.77, p = 0.02; CT: r = 0.71, p = 0.03).

Conclusion: Most erosions were detected using both modalities, but erosion scores were higher on CT than MR scans, especially at the metacarpal bases. It is possible that small erosions in some regions are more easily detected by CT because of its ability to clearly delineate cortical bony margins.

Citing Articles

Computed tomography-current status and future directions for arthritis imaging.

Ulas S, Diekhoff T Ther Adv Musculoskelet Dis. 2024; 16:1759720X241287373.

PMID: 39444595 PMC: 11497529. DOI: 10.1177/1759720X241287373.


Quantitative in vivo micro-computed tomography for monitoring disease activity and treatment response in a collagen-induced arthritis mouse model.

Lord A, Zhang L, Erickson J, Bryant S, Nelson C, Gaudette S Sci Rep. 2022; 12(1):2863.

PMID: 35190580 PMC: 8861028. DOI: 10.1038/s41598-022-06837-w.


CT-like images in MRI improve specificity of erosion detection in patients with hand arthritis: a diagnostic accuracy study with CT as standard of reference.

Ulas S, Ziegeler K, Richter S, Ohrndorf S, Poddubnyy D, Makowski M RMD Open. 2022; 8(1).

PMID: 35177555 PMC: 8860086. DOI: 10.1136/rmdopen-2021-002089.


Arthroscopically Assisted Eaton-Littler Trapeziometacarpal Ligamentoplasty.

Moungondo F, Gkotsi A, Camus E, Van Overstraeten L, Schuind F J Wrist Surg. 2021; 10(6):551-557.

PMID: 34881113 PMC: 8635835. DOI: 10.1055/s-0041-1731385.


[Rheumatoid arthritis of the hand : Part 2: Imaging].

Bollow M Radiologe. 2021; 61(4):362-374.

PMID: 33728480 DOI: 10.1007/s00117-021-00833-3.