» Articles » PMID: 15596568

Quantitative Assessment of Angiographic Restenosis After Sirolimus-eluting Stent Implantation in Native Coronary Arteries

Overview
Journal Circulation
Date 2004 Dec 15
PMID 15596568
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Sirolimus-eluting stents (SESs) reduce angiographic restenosis in patients with focal, native coronary artery stenoses. This study evaluated the usefulness of SESs in complex native-vessel lesions at high risk for restenosis.

Methods And Results: Angiographic follow-up at 240 days was obtained in 701 patients with long (15- to 25-mm) lesions in small-diameter (2.5- to 3.5-mm) native vessels who were randomly assigned to treatment with SESs or bare-metal stents (BMSs) in the SIRIUS trial. Quantitative angiographic measurements of minimal lumen diameter and percent diameter stenosis were obtained within the treated segment, within the stent, and within its 5-mm proximal and distal edges. Patients treated with SESs had lower rates of binary (>50% diameter stenosis) angiographic restenosis within the segment (8.9% versus 36.3% with the BMS; P<0.001) and within the stent (3.2% versus 35.4% with the BMS; P<0.001). SESs were associated with significantly less late lumen loss within the treated segment, within the stent, and within its 5-mm proximal and distal edges (all P<0.001). The reduction of restenosis with the SES was consistent in patients at risk for restenosis, including those with small vessels, long lesions, and diabetes mellitus. The frequency of late aneurysms was similar in the 2 groups.

Conclusions: Compared with BMSs, SESs reduced angiographic late lumen loss within the stent and its adjacent 5-mm margins in patients with complex native-vessel lesions.

Citing Articles

Effect of hemoglobin A1c management levels on coronary physiology evaluated by quantitative flow ratio in patients who underwent percutaneous coronary intervention.

Chen M, Liu J, Xie Z, Chen W, Hu Y, Wen J J Diabetes Investig. 2023; 15(3):336-345.

PMID: 38009857 PMC: 10906016. DOI: 10.1111/jdi.14114.


Coronary Artery Aneurysm After Drug-Eluting Stent Implantation Causing Coronary-Bronchial Fistula.

Gupta A, Datta R, Chhikara S, Dhagat P, Vijayvergiya R JACC Case Rep. 2021; 2(11):1692-1697.

PMID: 34317036 PMC: 8312138. DOI: 10.1016/j.jaccas.2020.07.041.


Effect of Low-Density Lipoprotein Cholesterol Goal Achievement on Vascular Physiology Evaluated by Quantitative Flow Ratio in Patients Who Underwent Percutaneous Coronary Intervention.

Chen L, Chen Q, Zhong J, Ye Z, Ye M, Yan Y Front Cardiovasc Med. 2021; 8:679599.

PMID: 34222375 PMC: 8249848. DOI: 10.3389/fcvm.2021.679599.


Physiological benefits evaluated by quantitative flow ratio in patients with reduced left ventricular ejection fraction who underwent percutaneous coronary intervention.

Zhong J, Chen Q, Chen L, Ye Z, Chen H, Sun J BMC Cardiovasc Disord. 2020; 20(1):523.

PMID: 33317462 PMC: 7737262. DOI: 10.1186/s12872-020-01814-5.


A rare complication of percutaneous coronary intervention: Coronary pseudoaneurysm formation.

Celik O, Bekar L, Yetim M, Dogan T, Alp C, Kalcik M Interv Med Appl Sci. 2018; 9(4):208-211.

PMID: 29951287 PMC: 6016209. DOI: 10.1556/1646.9.2017.33.