» Articles » PMID: 15570366

High-sensitivity Miniaturized Immunoassays for Tumor Necrosis Factor Alpha Using Microfluidic Systems

Overview
Journal Lab Chip
Specialties Biotechnology
Chemistry
Date 2004 Dec 1
PMID 15570366
Citations 36
Authors
Affiliations
Soon will be listed here.
Abstract

We use microfluidic chips to detect the biologically important cytokine tumor necrosis factor alpha (TNF- alpha) with picomolar sensitivity using sub-microliter volumes of samples and reagents. The chips comprise a number of independent capillary systems (CSs), each of which is composed of a filling port, an appended microchannel, and a capillary pump. Each CS fills spontaneously by capillary forces and includes a self-regulating mechanism that prevents adventitious drainage of the microchannels. Thus, interactive control of the flow in each CS is easily achieved via collective control of the evaporation in all CSs by means of two Peltier elements that can independently heat and cool. Long incubation times are crucial for high sensitivity assays and can be conveniently obtained by adjusting the evaporation rate to have low flow rates of approximately 30 nL min(-1). The assay is a sandwich fluorescence immunoassay and takes place on the surface of a poly(dimethylsiloxane)(PDMS) slab placed across the microchannels. We precoat PDMS with capture antibodies (Abs), localize the capture of analyte molecules using a chip, then bind the captured analyte molecules with fluorescently-tagged detection Abs using a second chip. The assay results in a mosaic of fluorescence signals on the PDMS surface which are measured using a fluorescence scanner. We show that PDMS is a compatible material for high sensitivity fluorescence assays, provided that detection antibodies with long excitation wavelength fluorophores ( > or =580 nm) are employed. The chip design, long incubation times, proper choice of fluorophores, and optimization of the detection Ab concentration all combine to achieve high-sensitivity assays. This is exemplified by an experiment with 170 assay sites, occupying an area of approximately 0.6 mm(2) on PDMS to detect TNF-alpha in 600 nL of a dendritic cell (DC) culture medium with a sensitivity of approximately 20 pg mL(-1)(1.14 pM).

Citing Articles

Microfluidics on lensless, semiconductor optical image sensors: challenges and opportunities for democratization of biosensing at the micro-and nano-scale.

Hu X, Abbasi R, Wachsmann-Hogiu S Nanophotonics. 2024; 12(21):3977-4008.

PMID: 39635640 PMC: 11501743. DOI: 10.1515/nanoph-2023-0301.


Three-Dimensional Microfluidic Capillary Device for Rapid and Multiplexed Immunoassays in Whole Blood.

Mortelmans T, Marty B, Kazazis D, Padeste C, Li X, Ekinci Y ACS Sens. 2024; 9(5):2455-2464.

PMID: 38687557 PMC: 11129352. DOI: 10.1021/acssensors.4c00153.


Enhanced capillary pumping using open-channel capillary trees with integrated paper pads.

Tokihiro J, Tu W, Berthier J, Lee J, Dostie A, Khor J Phys Fluids (1994). 2023; 35(8):082120.

PMID: 37675268 PMC: 10479884. DOI: 10.1063/5.0157801.


Atomic Scale Interactions between RNA and DNA Aptamers with the TNF- Protein.

Asadzadeh H, Moosavi A, Alexandrakis G, Mofrad M Biomed Res Int. 2021; 2021:9926128.

PMID: 34327241 PMC: 8310448. DOI: 10.1155/2021/9926128.


Tumor-Induced Inflammatory Cytokines and the Emerging Diagnostic Devices for Cancer Detection and Prognosis.

Kartikasari A, Huertas C, Mitchell A, Plebanski M Front Oncol. 2021; 11:692142.

PMID: 34307156 PMC: 8294036. DOI: 10.3389/fonc.2021.692142.