Large Efficiency Improvements in BEAMnrc Using Directional Bremsstrahlung Splitting
Overview
Authors
Affiliations
The introduction into the BEAMnrc code of a new variance reduction technique, called directional bremsstrahlung splitting (DBS), is described. DBS uses a combination of interaction splitting for bremsstrahlung, annihilation, Compton scattering, pair production and photoabsorption, and Russian Roulette to achieve a much better efficiency of photon beam treatment head simulations compared to the splitting techniques already available in BEAMnrc (selective bremsstrahlung splitting, SBS, and uniform bremsstrahlung splitting, UBS). In a simulated 6 MV photon beam (10 x 10 cm2 field) photon fluence efficiency in the beam using DBS is over 8 times higher than with optimized SBS and over 20 times higher than with UBS, with a similar improvement in electron fluence efficiency in the beam. Total dose efficiency in a central-axis depth-dose curve improves by a factor of 6.4 over SBS at all depths in the phantom. The performance of DBS depends on the details of the accelerator being simulated. At higher energies, the relative improvement in efficiency due to DBS decreases somewhat, but is still a factor of 3.5 improvement over SBS for total dose efficiency using DBS in a simulated 18 MV photon beam. Increasing the field size of the simulated 6 MV beam to 40 x 40 cm2 (broad beam) causes the relative efficiency improvement of DBS to decrease by a factor of approximately 1.7 but is still up to 7 times more efficient than with SBS.
E-Brachy: New dosimetry package for electronic brachytherapy sources.
Esmaelbeigi A, Kalinowski J, Tomic N, Rivard M, Vuong T, Devic S Med Phys. 2024; 52(1):662-672.
PMID: 39460996 PMC: 11700009. DOI: 10.1002/mp.17462.
TOPAS simulation of photoneutrons in radiotherapy: accuracy and speed with variance reduction.
Ramos-Mendez J, Ortiz C, Schuemann J, Paganetti H, Faddegon B Phys Med Biol. 2024; 69(11).
PMID: 38657630 PMC: 467037. DOI: 10.1088/1361-6560/ad4303.
Abuhaimed A, Mujammami H, Alenazi K, Abanomy A, Alashban Y, Martin C Phys Eng Sci Med. 2024; 47(3):895-906.
PMID: 38536632 DOI: 10.1007/s13246-024-01413-0.
Babapour H, Semyari S, Yadollahi M, Majdaeen M, Abedi-Firouzjah R, Ataei G Biomed Eng Comput Biol. 2022; 13:11795972221138473.
PMID: 36466131 PMC: 9716629. DOI: 10.1177/11795972221138473.
An independent Monte Carlo-based IMRT QA tool for a 0.35 T MRI-guided linear accelerator.
Khan A, Simiele E, Lotey R, DeWerd L, Yadav P J Appl Clin Med Phys. 2022; 24(2):e13820.
PMID: 36325743 PMC: 9924112. DOI: 10.1002/acm2.13820.