» Articles » PMID: 15519348

The Effect of Muscle Loading on the Simulation of Bone Remodelling in the Proximal Femur

Overview
Journal J Biomech
Specialty Physiology
Date 2004 Nov 3
PMID 15519348
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

A large number of finite element analyses of the proximal femur rely on a simplified set of muscle and joint contact loads to represent the boundary conditions of the model. In the context of bone remodelling analysis around hip implants, muscle loading affects directly the spatial distribution of the remodelling signal. In the present study we performed a sensitivity analysis on the effect of different muscle loading configurations on the outcome of the bone remodelling simulation. An anatomical model of the femur with the implanted stem in place was constructed using the CT data of the Visible Human Project dataset of the National Institute of Health. The model was loaded with three muscle force configurations with increasing level of complexity. A strain adaptive remodelling rule was employed to simulate the post-operative bone changes around the implant stem and the results of the simulation were assessed quantitatively in terms of the bone mineral content changes in 18 periprosthetic regions of interest. The results showed considerable differences in the amount of bone loss predicted between the three cases. The simplified models generally predicted more pronounced bone loss. Although the overall remodelling patterns observed were similar, the bone conserving effect of additional muscle forces in the vicinity of their areas of attachment was clear. The results of this study suggest that the loading configuration of the FE model does play an important role in the outcome of the remodelling simulation.

Citing Articles

Mechanical evaluation for the finite element analysis of intramedullary nailing and plate screw system used in humerus transverse fractures.

Akkurt E, Yildirim M, Erenler F, Tosun O, Akkurt M, Akkurt B J Orthop. 2024; 61:66-71.

PMID: 39411507 PMC: 11472024. DOI: 10.1016/j.jor.2023.10.024.


Hip reconstruction using a customized intercalary prosthesis with the rhino horn-designed uncemented stem for ultrashort proximal femur segments following tumor resection: a combined biomechanical and clinical study.

Hu X, Lu M, He X, Li L, Lin J, Zhou Y BMC Musculoskelet Disord. 2022; 23(1):852.

PMID: 36076197 PMC: 9454185. DOI: 10.1186/s12891-022-05805-9.


The effects of different cortical impingement scenarios on the biomechanical features of retrograde femoral nails in the management of distal femoral fractures: A finite element analysis.

Tasatan E, Kocadal O Acta Orthop Traumatol Turc. 2022; 56(3):173-177.

PMID: 35703504 PMC: 9612642. DOI: 10.5152/j.aott.2022.21212.


Multidirectional basketball activities load different regions of the tibia: A subject-specific muscle-driven finite element study.

Yan C, Bice R, Frame J, Warden S, Kersh M Bone. 2022; 159:116392.

PMID: 35314384 PMC: 10201946. DOI: 10.1016/j.bone.2022.116392.


Fatty Acid Composition of Proximal Femur Bone Marrow Adipose Tissue in Subjects With Systemic Lupus Erythematous Using 3 T Magnetic Resonance Spectroscopy.

Martel D, Saxena A, Belmont H, Honig S, Chang G J Magn Reson Imaging. 2021; 56(2):618-624.

PMID: 34964533 PMC: 10023192. DOI: 10.1002/jmri.28038.