» Articles » PMID: 1536984

Effective Dose Values in Bone Mineral Measurements by Photon Absorptiometry and Computed Tomography

Overview
Journal Osteoporos Int
Date 1992 Mar 1
PMID 1536984
Citations 35
Authors
Affiliations
Soon will be listed here.
Abstract

A high degree of uncertainty and irritation predominates in the assessment and comparison of radiation dose values resulting from measurements of bone mineral density of the lumbar spine by photon absorptiometry and X-ray computed tomography. The skin dose values which are usually given in the literature are of limited relevance because the size of the irradiated volumes, the relative sensitivity of the affected organs and the radiation energies are not taken into account. The concept of effective dose, sometimes called whole-body equivalent dose, has to be applied. A detailed analysis results in an effective dose value of about 1 microSv for absorptiometry and about 30 microSv for computed tomography when low kV and mAs values are used. Lateral localizer radiographs, which are necessary for slice selection in CT, mean an additional dose of 30 microSv. Lateral X-ray films of the spine which are frequently taken in combination with absorptiometry result in a dose of 700 microSv or more. The concept of effective dose, the basic data and assumptions used in its assessment and a comparison with other dose burdens (for example the natural background radiation, of typically 2400 microSv per year) are discussed in detail.

Citing Articles

Protocol for a randomized placebo-controlled clinical trial using pure palmitoleic acid to ameliorate insulin resistance and lipogenesis in overweight and obese subjects with prediabetes.

Cetin E, Pedersen B, Porter L, Adler G, Burak M Front Endocrinol (Lausanne). 2024; 14:1306528.

PMID: 38313838 PMC: 10835623. DOI: 10.3389/fendo.2023.1306528.


Diabetes mellitus among adult survivors of childhood acute lymphoblastic leukemia: A report from the St. Jude Lifetime Cohort Study.

Williams H, Howell C, Chemaitilly W, Wilson C, Karol S, Nolan V Cancer. 2019; 126(4):870-878.

PMID: 31714590 PMC: 6992468. DOI: 10.1002/cncr.32596.


Does Simultaneous Computed Tomography and Quantitative Computed Tomography Show Better Prescription Rate than Dual-energy X-ray Absorptiometry for Osteoporotic Hip Fracture?.

Ko J, Lim S, Han Lee Y, Yang I, Kam J, Park K Hip Pelvis. 2018; 30(4):233-240.

PMID: 30534542 PMC: 6284070. DOI: 10.5371/hp.2018.30.4.233.


Influence of fitness on health status among survivors of acute lymphoblastic leukemia.

Wilson C, Howell C, Partin R, Lu L, Kaste S, Mulrooney D Pediatr Blood Cancer. 2018; 65(11):e27286.

PMID: 30058279 PMC: 6150801. DOI: 10.1002/pbc.27286.


Clinical utilities of quantitative ultrasound in osteoporosis associated with inflammatory rheumatic diseases.

Oo W, Naganathan V, Bo M, Hunter D Quant Imaging Med Surg. 2018; 8(1):100-113.

PMID: 29541626 PMC: 5835660. DOI: 10.21037/qims.2018.02.02.


References
1.
Felsenberg D, Kalender W, Trinkwalter W, Wolf K . [CT examinations using a reduced radiation dosage]. Rofo. 1990; 153(5):516-21. DOI: 10.1055/s-2008-1033430. View

2.
VIRTAMA P . Uneven distribution of bone minerals and covering effect of non-mineralized tissue as reasons for impaired detectability of bone density from roentgenograms. Ann Med Intern Fenn. 1960; 49:57-65. View

3.
Shope T, GAGNE R, Johnson G . A method for describing the doses delivered by transmission x-ray computed tomography. Med Phys. 1981; 8(4):488-95. DOI: 10.1118/1.594995. View

4.
TRAUT H . [The effective dose equivalent: clarification and comments on the new dosage concept]. Rofo. 1989; 151(4):487-90. DOI: 10.1055/s-2008-1047221. View

5.
Gluer C, Steiger P, Genant H . Validity of dual-photon absorptiometry. Radiology. 1988; 166(2):574-5. DOI: 10.1148/radiology.166.2.3336739. View