A Method for Describing the Doses Delivered by Transmission X-ray Computed Tomography

Overview
Journal Med Phys
Specialty Biophysics
Date 1981 Jul 1
PMID 7322067
Citations 66
Authors
Affiliations
Soon will be listed here.
Abstract

A method for describing the absorbed dose delivered by x-ray transmission computed tomography (CT) is proposed which provides a means to characterize the dose resulting from CT procedures consisting of a series of adjacent scans. The dose descriptor chosen is the average dose at several locations in the imaged volume of the central scan of the series. It is shown that this average dose, as defined, for locations in the central scan of the series can be obtained from the integral of the dose profile perpendicular to the scan plane at these same locations for a single scan. This method for estimating the average dose from a CT procedure has been evaluated as a function of the number of scans in the multiple scan procedure and location in the dosimetry phantom using single scan dose profiles obtained from five different types of CT systems. For the higher dose regions in the phantoms, the multiple scan dose descriptor derived from the single scan dose profiles overestimates the multiple scan average dose by no more than 10%, provided the procedure consists of at least eight scans.

Citing Articles

Monte Carlo methods for medical imaging research.

Lee H Biomed Eng Lett. 2024; 14(6):1195-1205.

PMID: 39465109 PMC: 11502642. DOI: 10.1007/s13534-024-00423-x.


Impact of a novel multilayer imager on metal artifacts in MV-CBCT.

Harris T, Jacobson M, Myronakis M, Lehmann M, Huber P, Morf D Phys Med Biol. 2023; 68(14).

PMID: 37343590 PMC: 10382207. DOI: 10.1088/1361-6560/ace09a.


Validation of a New Scintillating Fiber Dosimeter for Radiation Dose Quality Control in Computed Tomography.

Guillochon N, Balde M, Popotte C, Pondard S, Desport C, Kien N Sensors (Basel). 2023; 23(5).

PMID: 36904817 PMC: 10007295. DOI: 10.3390/s23052614.


CAN THE SIZE-SPECIFIC DOSE ESTIMATE BE DERIVED FROM THE BODY MASS INDEX? A FEASIBILITY STUDY.

Steiniger B, Klippel C, Teichgraber U, Reichenbach J, Fiebich M Radiat Prot Dosimetry. 2022; 198(6):325-333.

PMID: 35443046 PMC: 9113340. DOI: 10.1093/rpd/ncac038.


Dependence of Water-equivalent Diameter and Size-specific Dose Estimates on CT Tube Potential.

McCollough C, McCollough S, Schneider J, Moen T, Weaver J, Vrieze T Radiology. 2022; 303(2):404-411.

PMID: 35040673 PMC: 9038617. DOI: 10.1148/radiol.210860.