The purpose of this study was to evaluate the diagnostic equivalence, radiation dose, clinical usefulness and radiographic aspects of a low-dose, full-body digital X-ray machine in a busy trauma unit. A digital trauma X-ray machine known as "LODOX" was compared with conventional radiography between June 1999 and November 2001 in the Groote Schuur Hospital Trauma Unit, Cape Town. Digital images of a variety of body regions commonly imaged in trauma were compared for diagnostic image quality in a number of categories with equivalent conventional radiographs. A seven-point equivalence scoring system ranging from much inferior (-3) through equivalent (0) to much superior (+3) was used in each category. Radiation dose was recorded and compared with that in conventional measurements. Turnaround times of patients undergoing digital and conventional X-rays were evaluated. Clinical and radiographic issues were assessed by staff feedback. The digital images when compared with conventional film had an overall mean equivalence score of -0.429, with a standard deviation (SD) of 0.77. The best digital performance was in the mediastinum (mean 0.346, SD 0.49) and the weakest was for bony detail (mean -0.654, SD 0.81). Relative digital radiation dose compared to conventional varied from 72% (chest) to 2% (pelvis), with a simple average of 6%. Radiographic points included full-body imaging capability and differing positioning, penetration, workflow and practicality considerations. The digital images required overall patient times of 5-6 min, compared with 8-48 min for conventional X-rays. New installations are under way, and computed tomography and angiography applications are being explored. FDA approval is awaited. Projected cost is similar to that of flat-panel digital units. This digital unit was felt to be diagnostically substantially equivalent to conventional radiographs, with low-dose full-body imaging, improved workflow, digital technology and long-term cost benefits as potentially favourable contributions to trauma imaging.

Citing Articles

Civilian gunshot injuries in orthopaedics: a narrative review of ballistics, current concepts, and the South African experience.

Laubscher M, Ferreira N, Birkholtz F, Graham S, Maqungo S, Held M Eur J Orthop Surg Traumatol. 2021; 31(5):923-930.

PMID: 33760996 DOI: 10.1007/s00590-021-02934-0.


Anterior-posterior view by full-body digital X-ray to rule out severe spinal injuries in Polytraumatized patients.

Hackel S, Hofmann E, Anwander H, Albers C, Basedow J, Bigdon S BMC Emerg Med. 2021; 21(1):27.

PMID: 33663394 PMC: 7934441. DOI: 10.1186/s12873-021-00419-1.


The Utility of Advanced Imaging in Forensic Anthropology.

Garvin H, Stock M Acad Forensic Pathol. 2019; 6(3):499-516.

PMID: 31239924 PMC: 6474549. DOI: 10.23907/2016.050.


Identification of ureteral stones at reduced radiation exposure: a pilot study comparing conventional versus digital low-dosage linear slot scanning (Lodox) radiography.

Fiechter S, Geissbuhler E, Bahler A, Obmann V, Meierhans S, Exadaktylos A World J Urol. 2019; 38(4):1065-1071.

PMID: 31165230 DOI: 10.1007/s00345-019-02803-w.


Reliability of photographic posture analysis of adolescents.

Hazar Z, Karabicak G, Tiftikci U J Phys Ther Sci. 2015; 27(10):3123-6.

PMID: 26644658 PMC: 4668149. DOI: 10.1589/jpts.27.3123.


References
1.
Aitken A, Flodmark O, Newman D, Kilcoyne R, Shuman W, Mack L . Leg length determination by CT digital radiography. AJR Am J Roentgenol. 1985; 144(3):613-5. DOI: 10.2214/ajr.144.3.613. View

2.
Buckwalter K, Braunstein E . Digital skeletal radiography. AJR Am J Roentgenol. 1992; 158(5):1071-80. DOI: 10.2214/ajr.158.5.1566670. View

3.
Bramble J, Murphey M . Comparison of digital and conventional musculoskeletal radiography: observer performance study. Radiology. 1990; 177(2):587-9. DOI: 10.1148/radiology.177.2.2278585. View

4.
Kushner D, Cleveland R, Herman T, McLoud T, Waltman A, Shepard J . Low-dose flying spot digital radiography of the chest: sensitivity studies. Radiology. 1987; 163(3):685-8. DOI: 10.1148/radiology.163.3.3575715. View

5.
Elam E, Rehm K, Hillman B, Maloney K, Fajardo L, McNeill K . Efficacy of digital radiography for the detection of pneumothorax: comparison with conventional chest radiography. AJR Am J Roentgenol. 1992; 158(3):509-14. DOI: 10.2214/ajr.158.3.1738985. View