» Articles » PMID: 15253450

Evaluation of a Cleavable Stable Isotope Labeled Synthetic Peptide for Absolute Protein Quantification Using LC-MS/MS

Overview
Journal J Proteome Res
Specialty Biochemistry
Date 2004 Jul 16
PMID 15253450
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Protein cleavage coupled with isotope dilution mass spectrometry (PC-IDMS) has the potential to provide the absolute concentration of a specific protein, or multiple proteins, in complex mixtures. However, PC-IDMS differs from standard IDMS since the internal standard is a different molecule than the analyte at the start of the experiment, more specifically, the internal standard is a peptide and the analyte is a protein prior to cleavage. It is not until after the cleavage process that the stable isotope labeled synthetic peptide has the same physicochemical behavior as the peptide cleaved from the protein. The work presented here evaluates the use of tryptic cleavage sites incorporated into the internal standard synthetic peptide in an attempt to create an internal standard that has cleavage characteristics more similar to the protein being quantified. Results presented here suggest that an internal standard synthetic peptide incorporating internal cleavage sites does not improve the accuracy and precision of the values obtained when performing PC-IDMS.

Citing Articles

A comparative study of synthetic winged peptides for absolute protein quantification.

Benesova E, Vidova V, Spacil Z Sci Rep. 2021; 11(1):10880.

PMID: 34035340 PMC: 8149832. DOI: 10.1038/s41598-021-90087-9.


The Time Has Come for Quantitative Protein Mass Spectrometry Tests That Target Unmet Clinical Needs.

Smit N, Ruhaak L, Romijn F, Pieterse M, van der Burgt Y, Cobbaert C J Am Soc Mass Spectrom. 2021; 32(3):636-647.

PMID: 33522792 PMC: 7944566. DOI: 10.1021/jasms.0c00379.


A novel potential primary method for quantification of enantiomers by high performance liquid chromatography-circular dichroism.

Luo Y, Wu L, Yang B, Jin Y, Zheng K, He Z Sci Rep. 2018; 8(1):7390.

PMID: 29743524 PMC: 5943587. DOI: 10.1038/s41598-018-25682-4.


LC-MS/MS Validation Analysis of Trastuzumab Using dSIL Approach for Evaluating Pharmacokinetics.

Budhraja R, Shah M, Suthar M, Yadav A, Shah S, Kale P Molecules. 2016; 21(11).

PMID: 27827861 PMC: 6274275. DOI: 10.3390/molecules21111464.


Impact of Sample Matrix on Accuracy of Peptide Quantification: Assessment of Calibrator and Internal Standard Selection and Method Validation.

Arnold S, Stevison F, Isoherranen N Anal Chem. 2015; 88(1):746-53.

PMID: 26606514 PMC: 4817721. DOI: 10.1021/acs.analchem.5b03004.