» Articles » PMID: 15228322

Piezoelectric Immunosensor for SARS-associated Coronavirus in Sputum

Overview
Journal Anal Chem
Specialty Chemistry
Date 2004 Jul 2
PMID 15228322
Citations 46
Authors
Affiliations
Soon will be listed here.
Abstract

A piezoelectric immunosensor was developed for the detection of SARS-associated coronavirus (SARS-CoV) in sputum in the gas phase. Horse polyclonal antibody against SARS-CoV was bound onto the PZ crystal surface in an ordered orientation through protein A. The antigen sample was atomized into aerosol by an ultrasonator, by which the antibody on the crystal could specifically adsorb SARS antigen and the changed mass of crystal would lead a frequency shift. A frequency counter was employed to record the admittance frequency, and the plot of changed frequency was displayed on the computer. Under the optimized conditions, the frequency shifts were linearly dependent on antigen concentration in the range of 0.6-4 microg/mL. The device has good reproducibility (could be reused 100 times without detectable loss of activity), stability (the immunosensor was stable for more than two months when stored over silica gel blue at 4-6 degrees C), short analyzing time (less than 2 min), and specificity.

Citing Articles

Sensing the Future-Frontiers in Biosensors: Exploring Classifications, Principles, and Recent Advances.

Manoharan Nair Sudha Kumari S, Thankappan Suryabai X ACS Omega. 2024; 9(50):48918-48987.

PMID: 39713646 PMC: 11656264. DOI: 10.1021/acsomega.4c07991.


Use of Immunoglobulin Y Antibodies: Biosensor-based Diagnostic Systems and Prophylactic and Therapeutic Drug Delivery Systems for Viral Respiratory Diseases.

Budama-Kilinc Y, Kurtur O, Gok B, Cakmakci N, Kecel-Gunduz S, Unel N Curr Top Med Chem. 2024; 24(11):973-985.

PMID: 38561616 DOI: 10.2174/0115680266289898240322073258.


Advances in nanobiosensors during the COVID-19 pandemic and future perspectives for the post-COVID era.

Kim Y, Min J Nano Converg. 2024; 11(1):3.

PMID: 38206526 PMC: 10784265. DOI: 10.1186/s40580-023-00410-5.


Batteryless wireless magnetostrictive FeCo/Ni clad plate for human coronavirus 229E detection.

Neyama D, Fakhruddin S, Inoue K, Kurita H, Osana S, Miyamoto N Sens Actuators A Phys. 2022; 349:114052.

PMID: 36447950 PMC: 9686060. DOI: 10.1016/j.sna.2022.114052.


Outlook of various diagnostics and nanodiagnostic techniques for COVID-19.

Preethi M, Roy L, Lahkar S, Borse V Biosens Bioelectron X. 2022; 12:100276.

PMID: 36345412 PMC: 9632232. DOI: 10.1016/j.biosx.2022.100276.