Abstract

For the analysis of trace organic pollutants in environmental samples using a gas chromatographic (GC) instrument, large-volume injection using the programmable temperature vaporization (PTV) technique has many advantages over the traditional split/splitless injection. By increasing the injection volume from 1 or 2 microL with a split/splitless inlet to 60 microL or higher with the PTV inlet, analytical sensitivity is greatly enhanced for analytes with low concentrations. Results obtained from optimization of instrument operational parameters for analyzing polycyclic aromatic hydrocarbons (PAHs) are reported in this paper. The laboratory method detection limits for 16 PAHs and six deuterated PAH surrogates were determined using seven replicate spike samples. The initial temperature of the inlet was found to be critical in determining the analytical sensitivity of PAHs with two or three rings due to loss of these relatively highly volatile compounds during solvent vaporization. For most PAHs, the response of the mass spectrometry detector increased proportionally as the total injected volume was increased up to 150 microL. Significant interference from rubber material of the sample vial septa was observed.

Citing Articles

Phase distribution and probabilistic risk assessment of polycyclic aromatic hydrocarbons in indoor air of coffee shops at Zahedan, Iran.

Sargazi S, Tabatabaei S, Ehrampoush M, Saravani R, Sakhvidi M, Fallahzadeh H Heliyon. 2024; 10(19):e36291.

PMID: 39386858 PMC: 11462464. DOI: 10.1016/j.heliyon.2024.e36291.


Levels of polycyclic aromatic hydrocarbon in the soil around typical automobile repair workshops in Nigeria.

Adesina O, Fakayode O, Lala M, Adewale A, Ademola Sonibare J F1000Res. 2024; 12.

PMID: 39183733 PMC: 11342030. DOI: 10.12688/f1000research.134682.3.


Parametric evaluation for programmable temperature vaporization large volume injection in gas chromatographic determination of polybrominated diphenyl ethers.

Wei H, Dassanayake P, Li A Int J Environ Anal Chem. 2010; 90(7):535-547.

PMID: 20383321 PMC: 2850545. DOI: 10.1080/03067310902871299.


Optimization of the matrix solid phase dispersion extraction procedure for the analysis of polybrominated diphenyl ethers in human placenta.

Dassanayake R, Wei H, Chen R, Li A Anal Chem. 2009; 81(23):9795-801.

PMID: 19863067 PMC: 2794305. DOI: 10.1021/ac901805d.