» Articles » PMID: 15107321

Reproducibility of Mammographic Classifications for Non-palpable Suspect Lesions with Microcalcifications

Overview
Journal Br J Radiol
Specialty Radiology
Date 2004 Apr 27
PMID 15107321
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Observer variability in interpretation of mammograms is a well-known problem, especially for microcalcifications. The classification of the mammographic findings depends upon this interpretation. We performed an intraobserver study to evaluate a breast imaging reporting and data system (BI-RADS) based method for description and classification of non-palpable lesions with microcalcifications. A set of 100 non-palpable mammographic lesions mainly consisting of microcalcifications was described and classified on two occasions, by two radiologists at an interval of 6 months. The intraobserver variability was evaluated with kappa statistics. The overall agreement for the classification was moderate (kappa 0.54). The lowest kappa values were observed for the categories "probably benign (BI-RADS 3, kappa 0.59)" and "suspicious abnormality (BI-RADS 4, kappa 0.44)". The clinical management (follow-up or biopsy) of non-palpable lesions consisting of microcalcifications depending upon radiological classification in the groups BI-RADS 3 (follow-up) and BI-RADS 4 (biopsy) is therefore debatable.

Citing Articles

The diagnostic value of MRI for architectural distortion categorized as BI-RADS category 3-4 by mammography.

Mei H, Xu J, Yao G, Wang Y Gland Surg. 2020; 9(4):1008-1018.

PMID: 32953609 PMC: 7475343. DOI: 10.21037/gs-20-505.


Delayed breast cancer diagnosis after repeated recall at biennial screening mammography: an observational follow-up study from the Netherlands.

Lameijer J, Voogd A, Pijnappel R, Setz-Pels W, Broeders M, Tjan-Heijnen V Br J Cancer. 2020; 123(2):325-332.

PMID: 32390006 PMC: 7374543. DOI: 10.1038/s41416-020-0870-2.


Simplifying Breast Imaging Reporting and Data System classification of mammograms with pure suspicious calcifications.

Menezes G, Winter-Warnars G, Koekenbier E, Groen E, Verkooijen H, Pijnappel R J Med Screen. 2017; 25(2):82-87.

PMID: 28691862 PMC: 5956567. DOI: 10.1177/0969141317715281.


Mammotome(®) and EnCor (®): comparison of two systems for stereotactic vacuum-assisted core biopsy in the characterisation of suspicious mammographic microcalcifications alone.

Mariscotti G, Durando M, Robella M, Angelino F, Regini E, Campanino P Radiol Med. 2014; 120(4):369-76.

PMID: 25120079 DOI: 10.1007/s11547-014-0452-6.


Role of magnetic resonance imaging in probably benign (BI-RADS category 3) microcalcifications of the breast.

Linda A, Zuiani C, Londero V, Di Gaetano E, Dal Col A, Girometti R Radiol Med. 2013; 119(6):393-9.

PMID: 24297595 DOI: 10.1007/s11547-013-0361-0.