Biomimetic and Electrolytic Calcium Phosphate Coatings on Titanium Alloy: Physicochemical Characteristics and Cell Attachment

Overview
Journal Biomaterials
Date 2003 Nov 11
PMID 14607496
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

Biomimetically deposited octacalcium phosphate (OCP) and carbonate apatite (BCA) as well as electrolytically deposited carbonate apatite (ECA) were considered as promising alternatives to conventional plasma spraying hydroxyapatite. This study compared their physicochemical characteristics and cell attachment behavior. The physicochemical characteristics included scanning electron microscopy observation, X-ray diffraction analysis, Fourier transform infrared spectroscopy analysis, surface roughness, coating thickness, dissolution test and scratch test. Cell attachment tests included morphology observation with stereomicroscopy and scanning electron microscopy as well as cell number count with DNA content assay. The OCP coating had 100% crystallinity and was about 40 microm thick, composed of large plate-like crystals of 30 microm, with the lowest surface roughness (R(a)=2.33 microm). The BCA coating had 60% crystallinity and was approximately 30 microm in thickness, composed of small crystals of 1-2 microm in size, with the highest surface roughness (R(a)=4.83 microm). The ECA coating had intermediate characteristics, with 78% crystallinity, 45 microm thickness, crystals of 5-6 microm and an average roughness of 3.87 microm. All coatings could be seen by eyes dissolving quickly and completely into acidic simulated body fluid (simulated physiological solutions-SPS, pH 3.0) but slowly and incompletely into neutral SPS (pH 7.3). It was suggested that the main factor determining coating dissolution in acidic SPS was the solubility isotherm, while some other factors including crystallinity and crystal size joined to determine coating dissolution in neutral SPS. In regard to adhesive strength, results of scratch test showed the critical load at the first crack of coating (L(c1)) was tightly related to crystal size as well as their arrangement, while the critical load at the total delamination of coating (L(c2)) was also related to the coating thickness. The ECA coating had the highest values. Owing to higher dissolution rate and globular appearance, BCA coating demonstrated the best goat bone marrow stromal cells attachment at 1 day or 3 days, followed by OCP and ECA coating.

Citing Articles

Improving the Bioactivity and Antibiofilm Properties of Metallic Implant Materials via Controlled Surface Microdeformation.

Bicer F, Toker S, Soykan M, Turk Yilmaz B, Yenice Gursu B, Uysal O ACS Omega. 2024; 9(42):43138-43155.

PMID: 39464454 PMC: 11500372. DOI: 10.1021/acsomega.4c07185.


Improving Biocompatibility for Next Generation of Metallic Implants.

Bandyopadhyay A, Mitra I, Goodman S, Kumar M, Bose S Prog Mater Sci. 2023; 133.

PMID: 36686623 PMC: 9851385. DOI: 10.1016/j.pmatsci.2022.101053.


Corrosion of Stirred Electrochemical Nano-Crystalline Hydroxyapatite (HA) Coatings on Ti6Al4V.

Ramaswamy N, Gopalan V, Kwon T Materials (Basel). 2022; 15(23).

PMID: 36500105 PMC: 9735767. DOI: 10.3390/ma15238609.


Crystalline Biomimetic Calcium Phosphate Coating on Mini-Pin Implants to Accelerate Osseointegration and Extend Drug Release Duration for an Orthodontic Application.

Li M, Wu G, Wang M, Hunziker E, Liu Y Nanomaterials (Basel). 2022; 12(14).

PMID: 35889663 PMC: 9324071. DOI: 10.3390/nano12142439.


Biofunctionalization of metallic implants by calcium phosphate coatings.

Su Y, Cockerill I, Zheng Y, Tang L, Qin Y, Zhu D Bioact Mater. 2019; 4:196-206.

PMID: 31193406 PMC: 6529680. DOI: 10.1016/j.bioactmat.2019.05.001.