» Articles » PMID: 14605897

Inter-test Reliability for Non-invasive Measures of Respiratory Muscle Function in Healthy Humans

Overview
Specialty Physiology
Date 2003 Nov 8
PMID 14605897
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

The aims of this study were to quantify the inter-test reliability of several voluntary, non-invasive measures of respiratory muscle function and to determine the implications of these data for studies using a repeated-measures design. Systematic measurement differences were found for 50% of the variables ( P</=0.05, t-tests). Nevertheless, 95% ratio limits of agreement for most measures proved acceptable and similar to those reported elsewhere. The random error component of the agreement ratios ranged from 1.047 to 1.149 for measures of pulmonary function in healthy subjects ( n=46), 1.045 to 1.056 for maximum static respiratory pressures ( n=24), 1.062 to 1.173 for measures relating to the maximum pressure-flow-power relationship ( n=16-22), and 1.036 to 1.071 for measures relating to maximum incremental inspiratory muscle performance ( n=12). The judgement that the limits of agreement were acceptable is supported by the sample-size calculations. Estimated sample sizes based upon an alpha level of 0.05 and a statistical power of 0.9 were mostly </=11 for a repeated-measures experimental design, particularly for the larger effect sizes (>/=5%). However, peak expiratory flow, the maximum rate of pressure development and the time constant of relaxation, require larger sample sizes to detect small within-group changes. In conclusion, the described protocols provide reliable measurements for most parameters of respiratory muscle function in healthy subjects. Furthermore, experiments utilising a within-subjects design lasting up to 3 weeks can be conducted with feasible sample sizes (</=11 per group) where substantial (>/=5%) changes are expected.

Citing Articles

Psychometric properties of volitional tests used to measure respiratory muscle strength and endurance: A systematic review.

Queiroz Pires T, Prata Martinez B, Marcos L, Resende Ramos I, Pinheiro V, Gomes Neto M Can J Respir Ther. 2025; 61:33-43.

PMID: 40062234 PMC: 11890114. DOI: 10.29390/001c.131842.


Reliability and Validity of Maximal Respiratory Pressures.

Silveira B, Pereira H, Chaves G, Ho D, Parreira V Respir Care. 2024; 69(7):881-890.

PMID: 38688546 PMC: 11285497. DOI: 10.4187/respcare.10641.


The test-retest reliability of physiological and perceptual responses during treadmill load carriage.

Vickery-Howe D, Dascombe B, Clarke A, Drain J, Huynh M, Middleton K Eur J Appl Physiol. 2024; 124(7):2093-2100.

PMID: 38418703 PMC: 11199236. DOI: 10.1007/s00421-024-05435-0.


Breathing a low-density gas reduces respiratory muscle force development and marginally improves exercise performance in master athletes.

Haddad T, Mons V, Meste O, Dempsey J, Abbiss C, Brisswalter J Eur J Appl Physiol. 2023; 124(2):651-665.

PMID: 37973652 DOI: 10.1007/s00421-023-05346-6.


Non-invasive assessment of fatigue and recovery of inspiratory rib cage muscles during endurance test in healthy individuals.

Wanderley E Lima T, Sarmento A, Vieira R, de Freitas Castro E, Pennati F, Aliverti A PLoS One. 2022; 17(12):e0277131.

PMID: 36477075 PMC: 9728934. DOI: 10.1371/journal.pone.0277131.


References
1.
McElvaney G, Fairbarn M, Wilcox P, Pardy R . Comparison of two-minute incremental threshold loading and maximal loading as measures of respiratory muscle endurance. Chest. 1989; 96(3):557-63. DOI: 10.1378/chest.96.3.557. View

2.
McElvaney G, Blackie S, Morrison N, Wilcox P, Fairbarn M, Pardy R . Maximal static respiratory pressures in the normal elderly. Am Rev Respir Dis. 1989; 139(1):277-81. DOI: 10.1164/ajrccm/139.1.277. View

3.
Larson J, Kim M . Reliability of maximal inspiratory pressure. Nurs Res. 1987; 36(5):317-9. View

4.
Tzelepis G, Zakynthinos S, Vassilakopoulos T, Geroulanos S, Roussos C . Inspiratory maneuver effects on peak expiratory flow. Role of lung elastic recoil and expiratory pressure. Am J Respir Crit Care Med. 1997; 156(5):1399-404. DOI: 10.1164/ajrccm.156.5.9702009. View

5.
Clanton T, Dixon G, Drake J, Gadek J . Inspiratory muscle conditioning using a threshold loading device. Chest. 1985; 87(1):62-6. DOI: 10.1378/chest.87.1.62. View