Effect of Saccharide Additives on Response of Ferrous-agarose-xylenol Orange Radiotherapy Gel Dosimeters

Overview
Journal Med Phys
Specialty Biophysics
Date 2003 Oct 8
PMID 14528948
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Glucose, sucrose, starch, and locust bean gum have been used as additives to the ferrous-agarose-xylenol orange (FAX) gel dosimeter. The saccharide enhanced dosimeters were found to have a higher dose sensitivity over a standard FAX gel as measured by both optical density change and magnetic resonance imaging (MRI). With optical density measurement, OD-dose sensitivity increases were up to 55% for glucose, 122% for sucrose and 43% for starch, while locust bean gum did not give a consistent response. With MRI, R1-dose sensitivity increases were up to 178% with sucrose addition. The FAX gel with sucrose was studied in greatest detail. The OD-dose sensitivity dependence on cooling rate was reduced for the sucrose FAX gel over the standard FAX gel, which has significant implications for uniform dose sensitivity in large gel phantoms. The thermal oxidation rate in the sucrose FAX gel was up to 2.3 times higher than in the standard gel. The OD-dose sensitivity of oxygenated sucrose FAX gels was 4.3 times greater than standard FAX gels, while continued enhancement in OD-dose sensitivity with increased sucrose concentrations beyond 2.0 g/l was found only for the oxygenated sucrose FAX gels. Both the molar absorption coefficient of the ferric ion-xylenol orange complex at 543 nm and gel pH were not affected by the presence of sucrose, with the implication that the higher OD-dose sensitivity of gels with saccharides is due to increased chain reaction production of ferric ions.

Citing Articles

Temperature Sensing in Agarose/Silk Fibroin Translucent Hydrogels: Preparation of an Environment for Long-Term Observation.

Micheva M, Baluschev S, Landfester K Nanomaterials (Basel). 2025; 15(2).

PMID: 39852738 PMC: 11767501. DOI: 10.3390/nano15020123.


Diffusion Correction in Fricke Hydrogel Dosimeters: A Deep Learning Approach with 2D and 3D Physics-Informed Neural Network Models.

Romeo M, Cottone G, DOca M, Bartolotta A, Gallo S, Miraglia R Gels. 2024; 10(9).

PMID: 39330168 PMC: 11431587. DOI: 10.3390/gels10090565.


Gel dosimetry has a viable future for dosimetry in the radiation oncology clinic.

Ceberg S, Olding T, Baldock C Phys Eng Sci Med. 2023; 47(1):1-5.

PMID: 38112936 DOI: 10.1007/s13246-023-01365-x.


Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

De Deene Y Gels. 2022; 8(9).

PMID: 36135311 PMC: 9498652. DOI: 10.3390/gels8090599.


How Xylenol Orange and Ferrous Ammonium Sulphate Influence the Dosimetric Properties of PVA-GTA Fricke Gel Dosimeters: A Spectrophotometric Study.

Scotti M, Arosio P, Brambilla E, Gallo S, Lenardi C, Locarno S Gels. 2022; 8(4).

PMID: 35448105 PMC: 9025870. DOI: 10.3390/gels8040204.