A Faster Method for 3D/2D Medical Image Registration--a Simulation Study

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2003 Sep 17
PMID 12974581
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

3D/2D patient-to-computed-tomography (CT) registration is a method to determine a transformation that maps two coordinate systems by comparing a projection image rendered from CT to a real projection image. Iterative variation of the CT's position between rendering steps finally leads to exact registration. Applications include exact patient positioning in radiation therapy, calibration of surgical robots, and pose estimation in computer-aided surgery. One of the problems associated with 3D/2D registration is the fact that finding a registration includes solving a minimization problem in six degrees of freedom (dof) in motion. This results in considerable time requirements since for each iteration step at least one volume rendering has to be computed. We show that by choosing an appropriate world coordinate system and by applying a 2D/2D registration method in each iteration step, the number of iterations can be grossly reduced from n6 to n5. Here, n is the number of discrete variations around a given coordinate. Depending on the configuration of the optimization algorithm, this reduces the total number of iterations necessary to at least 1/3 of it's original value. The method was implemented and extensively tested on simulated x-ray images of a tibia, a pelvis and a skull base. When using one projective image and a discrete full parameter space search for solving the optimization problem, average accuracy was found to be 1.0 +/- 0.6(degrees) and 4.1 +/- 1.9 (mm) for a registration in six parameters, and 1.0 +/- 0.7(degrees) and 4.2 +/- 1.6 (mm) when using the 5 + 1 dof method described in this paper. Time requirements were reduced by a factor 3.1. We conclude that this hardware-independent optimization of 3D/2D registration is a step towards increasing the acceptance of this promising method for a wide number of clinical applications.

Citing Articles

Colonoscopy 3D video dataset with paired depth from 2D-3D registration.

Bobrow T, Golhar M, Vijayan R, Akshintala V, Garcia J, Durr N Med Image Anal. 2023; 90:102956.

PMID: 37713764 PMC: 10591895. DOI: 10.1016/j.media.2023.102956.


Clinical Assessment of 2D/3D Registration Accuracy in 4 Major Anatomic Sites Using On-Board 2D Kilovoltage Images for 6D Patient Setup.

Li G, Yang T, Furtado H, Birkfellner W, Ballangrud A, Powell S Technol Cancer Res Treat. 2014; 14(3):305-14.

PMID: 25223323 PMC: 4544868. DOI: 10.1177/1533034614547454.


Robust 3D-2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation.

Otake Y, Wang A, Stayman J, Uneri A, Kleinszig G, Vogt S Phys Med Biol. 2013; 58(23):8535-53.

PMID: 24246386 PMC: 4915373. DOI: 10.1088/0031-9155/58/23/8535.


Validation for 2D/3D registration. II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set.

Gendrin C, Markelj P, Pawiro S, Spoerk J, Bloch C, Weber C Med Phys. 2011; 38(3):1491-502.

PMID: 21520861 PMC: 3089767. DOI: 10.1118/1.3553403.


Validation for 2D/3D registration. I: A new gold standard data set.

Pawiro S, Markelj P, Pernus F, Gendrin C, Figl M, Weber C Med Phys. 2011; 38(3):1481-90.

PMID: 21520860 PMC: 3091017. DOI: 10.1118/1.3553402.