A Method to Estimate in Vivo Dynamic Articular Surface Interaction

Overview
Journal J Biomech
Specialty Physiology
Date 2003 Aug 2
PMID 12893037
Citations 35
Authors
Affiliations
Soon will be listed here.
Abstract

This paper describes a method to calculate and visualize the proximity of subchondral bone surfaces during dynamic movement. This method combines high-speed biplane radiographic image data and three-dimensional (3D) bone surface information derived from computed tomography to determine subchondral bone motion during dynamic activities. Knowledge of in vivo subchondral bone motion may be useful in the study of osteoarthritis, in biomechanical modeling, and in identifying normal and pathological joint mechanics. This method can be used to identify the regions of close contact during dynamic motion, to calculate the surface area of subchondral bone within close contact, and to determine the changing position of the close contact area during dynamic activities. None of this informations can be obtained using other currently available 3D motion analysis techniques. Example applications showing dynamic in vivo tibio-femoral bone surface motion during canine gait and human one-legged hopping are presented.

Citing Articles

Load carriage changes tibiofemoral arthrokinematics during ambulatory tasks in recruit-aged women.

Johnson C, Dzewaltowski A, Dever D, Krajewski K, Rai A, Ahamed N Sci Rep. 2024; 14(1):9542.

PMID: 38664550 PMC: 11045865. DOI: 10.1038/s41598-024-60187-3.


Articular surface interactions distinguish dinosaurian locomotor joint poses.

Manafzadeh A, Gatesy S, Bhullar B Nat Commun. 2024; 15(1):854.

PMID: 38365765 PMC: 10873393. DOI: 10.1038/s41467-024-44832-z.


Improved joint function when reaching behind the back is associated with patient reported outcomes in individuals with rotator cuff tears following exercise therapy.

Mattar L, Johnson C, Gale T, Popchak A, Anderst W, Musahl V Clin Biomech (Bristol). 2024; 112:106184.

PMID: 38244237 PMC: 10922910. DOI: 10.1016/j.clinbiomech.2024.106184.


Does interpolation and intra-user variability affect the accuracy of arthrokinematic measurements in the knee? A dual fluoroscopic imaging and model-based tracking study.

Ramsdell J, Scott M, Beynnon B, Fiorentino N Med Eng Phys. 2023; 114:103968.

PMID: 37030894 PMC: 10115154. DOI: 10.1016/j.medengphy.2023.103968.


Associations between range of motion, strength, tear size, patient-reported outcomes, and glenohumeral kinematics in individuals with symptomatic isolated supraspinatus tears.

Mattar L, Popchak A, Anderst W, Musahl V, Irrgang J, Debski R J Shoulder Elbow Surg. 2022; 31(6):1261-1271.

PMID: 35091074 PMC: 9484487. DOI: 10.1016/j.jse.2021.12.032.