» Articles » PMID: 12860870

The Efficacy and Safety of Stent Redilatation in Congenital Heart Disease

Overview
Journal Heart
Date 2003 Jul 16
PMID 12860870
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: To assess the extent of neointimal proliferation and the safety and efficacy of stent redilatation in patients with stents implanted for aortic coarctation or branch pulmonary artery stenosis.

Design: Retrospective observational study.

Setting: Tertiary referral centre.

Patients And Interventions: Of 60 patients with Palmaz stents, 12 with coarctation and 12 with branch pulmonary artery stenosis (with 21 stented sites) underwent recatheterisation and stent redilatation.

Results: Neointimal thickening > 1 mm was detected in six of the 12 coarctation stents and at nine of the 21 stented sites in branch pulmonary arteries (five of which had been overdilated at implantation). Eight of the coarctation stents were electively underdilated at implantation. Coarctation stent redilatation increased median (range) lumen diameter from 9.2 (6.3-11.1) mm to 11.7 (9.8-14.1) mm (p = 0.002), decreased gradient from 10.5 (0-20) mm Hg to 0.5 (0-15) mm Hg (p = 0.008), and increased the ratio of stent diameter to descending aorta diameter from 0.66 (0.38-1.02) to 0.85 (0.52-1.2) (p = 0.008). Pulmonary artery stent redilatation increased lumen diameter from 6.9 (3.8-13.5) mm to 8.8 (4.8-14.1) mm (p < 0.001), decreased gradient from 24 (2-62) mm Hg to 12 (0-29) mm Hg (p < 0.001), and increased the ratio of stent diameter to diameter of distal pulmonary artery from 0.66 (0.44-1.5) to 0.86 (0.48-1.88) (p = 0.001). Dilatation of one peripheral pulmonary artery stent resulted in rupture of the vessel distal to the stent.

Conclusions: Neointimal proliferation is precipitated by overdilating stents at implantation. Redilatation using balloons matched to distal vessel diameter increases stent lumen size, but may not optimise vessel diameter. Redilatation is effective whether the indication for redilatation is a resistant stenosis at implantation, underexpansion at implantation, neointimal proliferation, or relative stenosis caused by growth.

Citing Articles

Initial status and 3-month results relating to the use of biodegradable nitride iron stents in children and the evaluation of right ventricular function.

Sun L, Li J, Xu Y, Xie Y, Wang S, Zhang Z Front Cardiovasc Med. 2022; 9:914370.

PMID: 35979021 PMC: 9376250. DOI: 10.3389/fcvm.2022.914370.


Pediatric tricuspid valve replacement with a transcatheter aortic valve (SAPIEN 3).

Kalangos A, Shatelen N, Sfyridis P, Dalarizou E, Bonou P JTCVS Tech. 2021; 6:121-124.

PMID: 34318167 PMC: 8300567. DOI: 10.1016/j.xjtc.2020.11.018.


The Potential Impact and Timeline of Engineering on Congenital Interventions.

Russell M, Blais B, Nia N, Levi D Pediatr Cardiol. 2020; 41(3):522-538.

PMID: 32198587 DOI: 10.1007/s00246-020-02335-w.


Dilating and fracturing side struts of open cell stents frequently used in pediatric cardiac interventions-An in vitro study.

Krasemann T, Kruit M, van der Mark A, Zeggelaar M, Dalinghaus M, van Beynum I J Interv Cardiol. 2018; 31(6):834-840.

PMID: 30091244 PMC: 6585776. DOI: 10.1111/joic.12549.


Stent Therapy for Aortic Coarctation in Children <30 kg: Use of the Low Profile Valeo Stent.

Kang S, Tometzki A, Taliotis D, Martin R Pediatr Cardiol. 2017; 38(7):1441-1449.

PMID: 28780709 DOI: 10.1007/s00246-017-1682-x.


References
1.
Bulbul Z, Bruckheimer E, Love J, Fahey J, Hellenbrand W . Implantation of balloon-expandable stents for coarctation of the aorta: implantation data and short-term results. Cathet Cardiovasc Diagn. 1996; 39(1):36-42. DOI: 10.1002/(SICI)1097-0304(199609)39:1<36::AID-CCD7>3.0.CO;2-3. View

2.
Mendelsohn A, Dorostkar P, Moorehead C, Lupinetti F, Reynolds P, Ludomirsky A . Stent redilation in canine models of congenital heart disease: pulmonary artery stenosis and coarctation of the aorta. Cathet Cardiovasc Diagn. 1996; 38(4):430-40. DOI: 10.1002/(SICI)1097-0304(199608)38:4<430::AID-CCD24>3.0.CO;2-H. View

3.
Shaffer K, Mullins C, Grifka R, OLaughlin M, McMahon W, Ing F . Intravascular stents in congenital heart disease: short- and long-term results from a large single-center experience. J Am Coll Cardiol. 1998; 31(3):661-7. DOI: 10.1016/s0735-1097(97)00535-4. View

4.
Suarez de Lezo J, Pan M, Romero M, Medina A, Segura J, Lafuente M . Immediate and follow-up findings after stent treatment for severe coarctation of aorta. Am J Cardiol. 1999; 83(3):400-6. DOI: 10.1016/s0002-9149(98)00877-7. View

5.
Magee A, Qureshi S, Rosenthal E, Zubrzycka M, Ksiazyk J, Tynan M . Stent implantation for aortic coarctation and recoarctation. Heart. 1999; 82(5):600-6. PMC: 1760772. DOI: 10.1136/hrt.82.5.600. View