» Articles » PMID: 12829906

The Hazards of Basing Acceptance of Cadaveric Renal Allografts on Pulsatile Perfusion Parameters Alone

Overview
Journal Transplantation
Specialty General Surgery
Date 2003 Jun 28
PMID 12829906
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Pulsatile perfusion (PP) is used by some centers to provide information that may aid in the selection of cadaveric renal allografts for transplantation. However, basing organ acceptance on PP parameters alone may lead to the discarding of kidneys from otherwise suitable donors. In this case series, we report the reevaluation and transplantation of kidneys refused by other centers after evaluation with PP.

Methods: Retrospective review of 14 cadaveric kidneys imported for repeat PP at our center after initially poor PP parameters from an outside organ procurement organization resulted in refusal by multiple centers.

Results: Median age of donors was 46 (range 21-64), and mean terminal serum creatinine was 1.3+/-0.6 mg/dL. Despite favorable donor characteristics, each kidney was refused by an average of 9.3 centers. Poor PP parameters and concerns about donor quality were the reasons for refusal in the majority of cases. Pulsatile-perfusion parameters at the outside center were poor: mean flow of 103 mL/min/100 g and mean resistance of 0.321 mm Hg/(mL/min/100 g). Repeat PP parameters at our center after importation were markedly improved (flow=167 mL/min/100 g and resistance=0.195 mm Hg/[mL/min/100 g]). Eleven of 14 kidneys were transplanted and currently have acceptable graft function (mean serum creatinine=1.6 mg/dL at a median follow-up of 12 months).

Conclusions: This series describes the successful transplantation of 11 kidneys from acceptable donors that were initially discarded by multiple centers after poor PP parameters were obtained. The good allograft function in these organs emphasizes the importance of considering all donor factors when making allocation decisions.

Citing Articles

Can We Predict Kidney Graft Function and Graft Survival Using Hypothermic Machine Perfusion Parameters From Donors After Circulatory Death?.

Offerni J, Li E, Matti D, Luke G, Luke P, Sener A Transplant Direct. 2024; 10(4):e1601.

PMID: 38464425 PMC: 10923389. DOI: 10.1097/TXD.0000000000001601.


Machine perfusion of kidney allografts affects early but not late graft function.

Singh N, Logan A, Schenk A, Bumgardner G, Brock G, El-Hinnawi A Am J Surg. 2021; 223(4):804-811.

PMID: 34253338 PMC: 9017432. DOI: 10.1016/j.amjsurg.2021.06.019.


Decrease of renal resistance during hypothermic oxygenated machine perfusion is associated with early allograft function in extended criteria donation kidney transplantation.

Meister F, Czigany Z, Rietzler K, Miller H, Reichelt S, Liu W Sci Rep. 2020; 10(1):17726.

PMID: 33082420 PMC: 7575556. DOI: 10.1038/s41598-020-74839-7.


Beneficial Effect of Moderately Increasing Hypothermic Machine Perfusion Pressure on Donor after Cardiac Death Renal Transplantation.

Ding C, Tian P, Ding X, Xiang H, Li Y, Tian X Chin Med J (Engl). 2018; 131(22):2676-2682.

PMID: 30425194 PMC: 6247599. DOI: 10.4103/0366-6999.245274.


Association of lower costs of pulsatile machine perfusion in renal transplantation from expanded criteria donors.

Buchanan P, Lentine K, Burroughs T, Schnitzler M, Salvalaggio P Am J Transplant. 2008; 8(11):2391-401.

PMID: 18925906 PMC: 2596761. DOI: 10.1111/j.1600-6143.2008.02412.x.