A chemically modified electrode based on the carbon nanotube film-coated glassy carbon electrode (GCE) is described for the simultaneous determination of dopamine (DA) and serotonin (5-HT). The multiwall carbon nanotube (MWNT) film-coated GCE exhibits a marked enhancement effect on the current response of DA and 5-HT and lowers oxidation overpotentials. The responses of DA and 5-HT merge into a large peak at a bare GCE, but they yield two well-defined oxidation peaks at the MWNT film-coated GCE. The experimental parameters were optimized, and a direct electrochemical method for the simultaneous determination of DA and 5-HT was proposed. The interference of ascorbic acid (AA) was investigated, and the results showed that a large excess of AA did not interfere with the voltammetric responses of DA and 5-HT. The modified electrode has been successfully applied for the assay of 5-HT and DA in human blood serum.

Citing Articles

Eco-friendly electrochemical assay of oxytetracycline and flunixin in their veterinary injections and spiked milk samples.

Trabik Y, Ayad M, Mahmoud A, Abdullatif H, Michael A BMC Chem. 2024; 18(1):179.

PMID: 39300585 PMC: 11411790. DOI: 10.1186/s13065-024-01282-4.


Sialic Acid-Functionalized Gold Nanoparticles for Sensitive and Selective Colorimetric Determination of Serotonin.

Avci B, Akpinar Y, Ertas G, Volkan M ACS Omega. 2024; 9(22):23832-23842.

PMID: 38854544 PMC: 11154895. DOI: 10.1021/acsomega.4c01859.


Electrodeposited reduced graphene oxide-PEDOT:PSS/Nafion hybrid interface for the simultaneous determination of dopamine and serotonin.

Ko S, Kim S, Lee S, Lee Y Sci Rep. 2023; 13(1):20274.

PMID: 37985920 PMC: 10662300. DOI: 10.1038/s41598-023-47693-6.


Advances on Hormones and Steroids Determination: A Review of Voltammetric Methods since 2000.

Smajdor J, Paczosa-Bator B, Piech R Membranes (Basel). 2022; 12(12).

PMID: 36557132 PMC: 9782681. DOI: 10.3390/membranes12121225.


Graphene-Based Sensor for the Detection of Cortisol for Stress Level Monitoring and Diagnostics.

Zubarev A, Cuzminschi M, Iordache A, Iordache S, Rizea C, Grigorescu C Diagnostics (Basel). 2022; 12(11).

PMID: 36359436 PMC: 9689560. DOI: 10.3390/diagnostics12112593.