» Articles » PMID: 12202710

Aortic and Hepatic Enhancement and Tumor-to-liver Contrast: Analysis of the Effect of Different Concentrations of Contrast Material at Multi-detector Row Helical CT

Overview
Journal Radiology
Specialty Radiology
Date 2002 Aug 31
PMID 12202710
Citations 45
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate the effect of different iodine concentrations of contrast material on aortic and hepatic enhancement and the detectability of hypervascular hepatocellular carcinoma (HCC) with multi-detector row computed tomography (CT) and a uniphasic contrast material injection technique.

Materials And Methods: Two hundred one patients with known or who were suspected of having HCC underwent multi-detector row CT; 58 patients with hypervascular HCC were identified. First-, second-, and third-phase scanning was started with the aortic arrival times plus 15 seconds, plus 30 seconds, and plus 105 seconds, respectively. All patients were assigned randomly into two groups. Patients in groups A and B received iopamidol with an iodine concentration of 300 mg/mL and 370 mg/mL, respectively, with the same total iodine load per patient per body weight. The liver and aorta enhancement and tumor-to-liver contrast (TLC) were measured. Depiction of hepatic arteries was evaluated visually by two radiologists.

Results: During the first phase, aortic enhancement was significantly (P <.01) higher in group B, with no significant difference in hepatic enhancement between the two groups. During the second phase, aortic enhancement was significantly (P <.01) higher in group A, with no significant difference in hepatic enhancement. The TLC was significantly (P <.01) higher in group B during the first phase, but there was no significant difference between the two groups during the second phase. There was no significant difference in any parameters between the two groups during the third phase. Depiction of the hepatic arteries in group B was significantly (P <.05) superior to that in group A.

Conclusion: In the arterial phase, administration of a higher concentration of contrast material is effective for a significantly higher TLC.

Citing Articles

Computed tomography image quality in patients with primary hepatocellular carcinoma: intraindividual comparison of contrast agent concentrations.

Peng F, Luo C, Ning X, Xiao F, Guan K, Tang C Front Med (Lausanne). 2024; 11:1460505.

PMID: 39478815 PMC: 11521877. DOI: 10.3389/fmed.2024.1460505.


Feasibility of a single-phase portal venous CT protocol using bolus tracking technique and lean body weight-based contrast media dose.

Valletta R, Bonatti M, Vingiani V, Corato V, Proner B, Lombardo F Eur Radiol. 2024; 35(2):1067-1075.

PMID: 39122853 DOI: 10.1007/s00330-024-11009-7.


The Image Quality and Diagnostic Performance of CT with Low-Concentration Iodine Contrast (240 mg Iodine/mL) for the Abdominal Organs.

Choi M, Lee Y, Jung S Diagnostics (Basel). 2022; 12(3).

PMID: 35328304 PMC: 8947528. DOI: 10.3390/diagnostics12030752.


Comparison of the Value of Color Doppler Ultrasound and Multislice Spiral CT in the Differential Diagnosis of Benign and Malignant Nodules in the Liver.

Jia P, Liu R, Liu Y, Wu Y, Dou T Contrast Media Mol Imaging. 2022; 2022:5251966.

PMID: 35185409 PMC: 8828348. DOI: 10.1155/2022/5251966.


Image quality improvement with deep learning-based reconstruction on abdominal ultrahigh-resolution CT: A phantom study.

Shirasaka T, Kojima T, Funama Y, Sakai Y, Kondo M, Mikayama R J Appl Clin Med Phys. 2021; 22(7):286-296.

PMID: 34159736 PMC: 8292685. DOI: 10.1002/acm2.13318.