» Articles » PMID: 12135544

The Traumatic Spondylolisthesis of the Axis. A Biomechanical in Vitro Evaluation of an Instability Model and Clinical Relevant Constructs for Stabilization

Overview
Date 2002 Jul 24
PMID 12135544
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Stepwise destabilization of the traumatic spondylolisthesis C2 with an increasing anterior defect of C2-C3 was investigated. The three-dimensional stabilizing capabilities of posterior transpedicle screw osteosynthesis and two anterior plate systems C2-C3, the H-plate and the titanium locking plate were tested.

Design: A biomechanical in vitro study was performed using a standardized experimental protocol in a spine tester.

Background: The extent of the instability of the traumatic spondylolisthesis of C2 within its different types remains unclear. Posterior and anterior approaches for stabilization exist for patients with isthmusfractures at C2, the stabilizing effect has not been demonstrated yet.

Methods: The motion levels from C2-C3 in six human specimen were tested in flexion, extension, right and left lateral bending and left and right axial rotation. The specimens were tested intact, after destabilization and after stabilization.

Results: In extension and axial rotation, each step of destabilization decreased the moment significantly, to achieve the range of motion of the intact specimen. In flexion a statistical significant destabilization after separation of the posterior longitudinal ligament was present. The flexibility tests showed an increasing range of motion of the posterior transpedicle screws, with increasing anterior instability markedly in flexion and extension. After H-plate and locking plate fixation, a significant decrease of the range of motion resulted in flexion. The stiffness in flexion and extension increased consecutively, while in lateral bending and axial rotation the transpedicle screw fixation showed the highest stiffness.

Conclusions/relevance: The traumatic spondylolisthesis of C2 is a significantly unstable injury in case of additional segmental damage of C2-C3. Anterior stabilization in these injuries is mandatory.

Citing Articles

Range of Motion and Neutral Zone of All Human Spinal Motion Segments: A Data Collection of 30 Years of In Vitro Experiments Performed Under Standardized Testing Conditions.

Wilke H, Kienle A, Werner K, Liebsch C JOR Spine. 2025; 8(1):e70052.

PMID: 40046266 PMC: 11881816. DOI: 10.1002/jsp2.70052.


Current Concepts in the Treatment of Traumatic C2 Vertebral Fracture : A Literature Review.

Lee S, Hur J, Oh Y, An S, Yun G, Ahn J J Korean Neurosurg Soc. 2023; 67(1):6-13.

PMID: 37461838 PMC: 10788552. DOI: 10.3340/jkns.2023.0098.


Saradhi's single stage, anterior sequential reduction utilizing C3 for type III hangman's fracture: A novel technique.

Mudumba V, Pavan S, Alugolu R J Craniovertebr Junction Spine. 2022; 13(1):80-84.

PMID: 35386244 PMC: 8978851. DOI: 10.4103/jcvjs.jcvjs_83_21.


Treatment of Axis Ring Fractures: Recommendations of the Spine Section of the German Society for Orthopaedics and Trauma (DGOU).

Scholz M, Kandziora F, Kobbe P, Matschke S, Schleicher P, Josten C Global Spine J. 2018; 8(2 Suppl):18S-24S.

PMID: 30210957 PMC: 6130108. DOI: 10.1177/2192568217745061.


Burst C2 Fractures Combined with Traumatic Spondylolisthesis: Can Atlantoaxial Motion Be Preserved? Including Some Technical Tips for Reduction and Fixation.

Assaghir Y Global Spine J. 2016; 6(6):555-62.

PMID: 27555997 PMC: 4993615. DOI: 10.1055/s-0035-1569461.