[Equipment of Physician-staffed Ambulance Systems in the State of Baden-Wuerttemberg]

Overview
Journal Anaesthesist
Specialty Anesthesiology
Date 2002 Jul 20
PMID 12125307
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Laws regulating emergency medical systems in the federal state of Baden-Wuerttemberg call for equipment of physician-staffed ambulances that is based on current knowledge in emergency medicine. The grade of implementation is determined using single issue complexes.

Methods: A total of 127 emergency physician bases were located and each received a questionnaire regarding the equipment of the physician-staffed ambulances and helicopters and planned supplementation of the equipment, deadline was 30 June 2001.

Results: Of the 127 stations 116 (91.3%) participated. A 12-lead ECG is available in 52.6%, out-of-hospital fibrinolysis is possible in 15 bases (12.9%). Alternatives to endotracheal intubation are carried in 53.3% (cricothyroidotomy: 83.3%) and 31 bases provide capnometry or other devices for verifying correct tube placement. A mobile phone is available in 88 bases (75.9%).

Conclusions: When comparing equipment of physician-staffed ambulances statewide, striking differences can be found.

Citing Articles

A comparison of fiberoptical guided tracheal intubation via laryngeal mask and laryngeal tube.

Metterlein T, Plank C, Sinner B, Bundscherer A, Graf B, Roth G Saudi J Anaesth. 2015; 9(1):37-41.

PMID: 25558197 PMC: 4279348. DOI: 10.4103/1658-354X.146285.


[Supraglottic airway devices in emergency medicine : impact of gastric drainage].

Mann V, Mann S, Alejandre-Lafont E, Rohrig R, Weigand M, Muller M Anaesthesist. 2013; 62(4):285-92.

PMID: 23494024 DOI: 10.1007/s00101-013-2154-1.


The quality of emergency medical care in baden-württemberg (Germany): four years in focus.

Messelken M, Kehrberger E, Dirks B, Fischer M Dtsch Arztebl Int. 2010; 107(30):523-30.

PMID: 20737058 PMC: 2925343. DOI: 10.3238/arztebl.2010.0523.


[E-health in emergency medicine - the research project Med-on-@ix].

Skorning M, Bergrath S, Rortgen D, Brokmann J, Beckers S, Protogerakis M Anaesthesist. 2009; 58(3):285-92.

PMID: 19221700 DOI: 10.1007/s00101-008-1502-z.


[Preclinical transtracheal emergency ventilation. Animal experimental comparison of two techniques].

Schwarzkopf K, Huter L, Preussler N, Schafer R, Schreiber T Anaesthesist. 2007; 56(11):1115-9.

PMID: 17639282 DOI: 10.1007/s00101-007-1233-6.