Determination of Nitrite in Foods by Single-sweep Polarography
Overview
Authors
Affiliations
In an acid medium, nitrite diazotized with p-rosaniline and then coupled with 8-hydroxyquinoline in a weak alkaline medium produces azo compounds. The azo compounds produce a very sensitive polarographic wave at -0.70 V (versus the saturated calomel electrode). The height of the peak is linear with the concentration of nitrite in the range of 5 x 10(-9) to 5 x 10(-7) g/mL. The detection limit is 3 x 10(-9) g/mL. The electrochemical characteristics of the polarographic wave are also discussed. The method was used to determine nitrite in sausage. The results agree well with those obtained by spectrophotometry.
Zhao J, Xia H, Yu T, Jin L, Li X, Zhang Y PLoS One. 2018; 13(4):e0194010.
PMID: 29677193 PMC: 5909897. DOI: 10.1371/journal.pone.0194010.