» Articles » PMID: 11863207

Respiratory Rate Measurement in Adults--how Reliable is It?

Overview
Journal Respir Med
Publisher Elsevier
Specialty Pulmonary Medicine
Date 2002 Feb 28
PMID 11863207
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Measurement of respiratory rate (RR) is essential in the evaluation of respiratory disorders. However, the variability in RR measurement in adults has never been adequately assessed. Respiratory rate was measured twice in 245 patients; the two measurements were performed by the same observer in 137 patients, by different observers in 58 patients and simultaneously by different observers in 50 patients. The mean (SD) difference between the first and second measurements was 0.03 (3); 95% limits of agreement-4.86-4.94 breaths min(-1), -5.7-5.7 breaths min(-1), and -4.2 to 4.4 breaths min(-1) for the same observer, different observer and simultaneous observer groups, respectively. The difference in RR measurements did not vary with RR. In conclusions on average, there is very good agreement between observers in RR measurement. Inter-observer variability may account for a difference of up to 6 breaths min(-1). This is relevant when applying clinical prediction rules based on threshold RR values.

Citing Articles

Low compression smart clothing for respiratory rate monitoring using a bending angle sensor based on double-layer capacitance.

Kobayashi T, Goto D, Sakaue Y, Okada S, Shiozawa N Biomed Eng Lett. 2025; 15(2):389-399.

PMID: 40026894 PMC: 11871213. DOI: 10.1007/s13534-025-00456-w.


A Hierarchical Framework for Selecting Reference Measures for the Analytical Validation of Sensor-Based Digital Health Technologies.

Bakker J, McClenahan S, Fromy P, Turner S, Peterson B, Vandendriessche B J Med Internet Res. 2025; 27:e58956.

PMID: 39918870 PMC: 11845878. DOI: 10.2196/58956.


Contactless and continuous monitoring of respiratory rate in a hospital ward: a clinical validation study.

Toften S, Kjellstadli J, Kvaerness J, Pedersen L, Laugsand L, Thu O Front Physiol. 2024; 15:1502413.

PMID: 39665054 PMC: 11631942. DOI: 10.3389/fphys.2024.1502413.


A ballistocardiogram dataset with reference sensor signals in long-term natural sleep environments.

Li Y, Huang J, Yao X, Mu S, Zong S, Shen Y Sci Data. 2024; 11(1):1091.

PMID: 39368975 PMC: 11455873. DOI: 10.1038/s41597-024-03950-5.


Reliable Contactless Monitoring of Heart Rate, Breathing Rate, and Breathing Disturbance During Sleep in Aging: Digital Health Technology Evaluation Study.

Ravindran K, Monica C, Atzori G, Lambert D, Hassanin H, Revell V JMIR Mhealth Uhealth. 2024; 12:e53643.