Collarless Polished Tapered Stem: Clinical and Radiological Follow-up over 5 Years

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2002 Feb 16
PMID 11847618
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

The clinical and radiologic outcome of a cemented, polished, tapered stem (CPT), implanted using contemporary cementing techniques in 108 consecutive operated hips in 100 patients (68 women and 32 men, aged 19 to 83 years at the time of surgery [mean, 65 years]) was assessed after >5 years. The Harris hip scores were good or excellent in 96% of the patients. Stem subsidence measured by the computer-assisted method described by Braud and Freeman was at a mean rate of 0.44 mm/y, 1.08 mm during the first year, and stabilizing to a mean total of 2.18 mm at >5 years. Subsidence was related inversely to the completeness of the cement mantle but did not correlate with the clinical or radiologic outcome. This study confirms that collarless, polished, tapered stems subside within the cement mantle but without loosening and that the CPT performs at least as well as the Exeter stem.

Citing Articles

A 2-year prospective clinical and bone density evaluation, with a subset undergoing radiostereometric analysis, using the Absolut cemented stem.

Ebert J, Nivbrant N, Petrov V, Yates P, Wood D ANZ J Surg. 2022; 92(4):830-836.

PMID: 35106881 PMC: 9303330. DOI: 10.1111/ans.17519.


Temporal subsidence patterns of cemented polished taper-slip stems: a systematic review.

Baryeh K, Mendis J, Sochart D EFORT Open Rev. 2021; 6(5):331-342.

PMID: 34150327 PMC: 8183154. DOI: 10.1302/2058-5241.6.200086.


Initial evaluation on subsidence of cemented collarless polished tapered stem applied to the patients with narrow femoral medullar canal.

Dairaku K, Ishii M, Kobayashi S, Kawaji H, Sasaki K, Takakubo Y Open Orthop J. 2010; 4:147-51.

PMID: 20448819 PMC: 2864431. DOI: 10.2174/1874325001004010147.


Stem subsidence of polished and rough double-taper stems: in vitro mechanical effects on the cement-bone interface.

Kaneuji A, Yamada K, Hirosaki K, Takano M, Matsumoto T Acta Orthop. 2009; 80(3):270-6.

PMID: 19421909 PMC: 2823200. DOI: 10.3109/17453670902967265.


The relationship between stem subsidence and improvement in the radiolucency in polished tapered stems.

Kaneuji A, Sugimori T, Ichiseki T, Fukui K, Yamada K, Matsumoto T Int Orthop. 2006; 30(5):387-90.

PMID: 16614823 PMC: 3172779. DOI: 10.1007/s00264-006-0112-0.