» Articles » PMID: 11835613

Volumetric Model Determination of the Tibia Based on 2D Radiographs Using a 2D/3D Database

Overview
Date 2002 Feb 9
PMID 11835613
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

We present a new concept with mathematical background for the construction of a three-dimensional (3D) volumetric model of the human tibia based on two conventional orthogonal two-dimensional (2D) radiographic images. This approach is supported by a computer database containing a collection of 80 2D/3D image data sets of individual cadaveric tibiae. For each of these tibiae, the database contains digitized 2D orthogonal radiographic images in both anterior and lateral views, and the corresponding 3D CT data obtained by computerized tomography. To obtain a 3D model of a tibia for a given patient, shape matching is performed. The computer finds the most similar tibia to the patient's tibia among the 2D radiographic images in the database by applying a matching process. To improve accuracy, a 2D image warping procedure can be applied on the slices of the selected bone prior to 3D reconstruction. The warping process is controlled by the contour data of the two orthogonal views. We found that the 3D model thus achieved was useful for virtual preoperative planning and for simulation of the internal fixation of long bones.

Citing Articles

Computer-assisted preoperative planning of bone fracture fixation surgery: A state-of-the-art review.

Moolenaar J, Tumer N, Checa S Front Bioeng Biotechnol. 2022; 10:1037048.

PMID: 36312550 PMC: 9613932. DOI: 10.3389/fbioe.2022.1037048.


Reliability and concurrent validity of angle measurements in lower limb: EOS 3D goniometer versus 2D manual goniometer.

Huang J, Tian F, Zhang Z, Shi W, Lin J, Chen L J Orthop Translat. 2020; 24:96-102.

PMID: 32775201 PMC: 7390786. DOI: 10.1016/j.jot.2020.05.002.


Radiographic reconstruction of lower-extremity bone fragments: a first trial.

Schumann S, Bieck R, Bader R, Heverhagen J, Nolte L, Zheng G Int J Comput Assist Radiol Surg. 2016; 11(12):2241-2251.

PMID: 27311824 DOI: 10.1007/s11548-016-1427-y.


3D patient-specific model of the tibia from CT for orthopedic use.

Gonzalez-Carbonell R, Ortiz-Prado A, Jacobo-Armendariz V, Cisneros-Hidalgo Y, Alpizar-Aguirre A J Orthop. 2015; 12(1):11-6.

PMID: 25829755 PMC: 4354529. DOI: 10.1016/j.jor.2015.01.009.


Metal artifacts from titanium and steel screws in CT, 1.5T and 3T MR images of the tibial Pilon: a quantitative assessment in 3D.

Radzi S, Cowin G, Robinson M, Pratap J, Volp A, Schuetz M Quant Imaging Med Surg. 2014; 4(3):163-72.

PMID: 24914417 PMC: 4032923. DOI: 10.3978/j.issn.2223-4292.2014.03.06.