» Articles » PMID: 1178154

The Emmetropic and the Iseikonic Implant Lens: Computer Calculation of the Refractive Power and Its Accuracy

Overview
Journal Ophthalmologica
Publisher Karger
Specialty Ophthalmology
Date 1975 Jan 1
PMID 1178154
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

The preoperative calculation of the power of a lens prosthesis and the resulting aniseikonia is given, as well as diagrams for reading the emmetropizing and the iseikonizing power of the lens. The consequences of an inaccuracy in the measurement of the dimensional and refractive properties of the eyes are calculated. It can be concluded that the main determinant for an accurate prediction of the power of the intraocular lens prosthesis is the axial length measurement. Since this measurement is carried out by means of ultrasound biometry, it is necessary to emphasize the adequate application of this technique. The problem as to whether an emmetropizing, or an iseikonizing lens should be implanted may be solved with the data supplied by the computer program. A flow chart for this program is given in an appendix.

Citing Articles

An ensemble-based approach for estimating personalized intraocular lens power.

Moutari S, Moore J Sci Rep. 2021; 11(1):22961.

PMID: 34824338 PMC: 8617163. DOI: 10.1038/s41598-021-02288-x.


Focused ultrasound in ophthalmology.

Silverman R Clin Ophthalmol. 2016; 10:1865-1875.

PMID: 27757007 PMC: 5053390. DOI: 10.2147/OPTH.S99535.


Evaluation of ultrasound velocity in enucleated equine aqueous humor, lens and vitreous body.

Meister U, Ohnesorge B, Korner D, Boeve M BMC Vet Res. 2014; 10:250.

PMID: 25312851 PMC: 4205291. DOI: 10.1186/s12917-014-0250-3.


Factors influencing the accuracy of the SRK formula in the intraocular less power calculation.

Kalogeropoulos C, Aspiotis M, Stefaniotou M, Psilas K Doc Ophthalmol. 1994; 85(3):223-42.

PMID: 7924850 DOI: 10.1007/BF01664930.


Hereditary retinitis pigmentosa: recent findings from electroretinography, fundus reflectometry, and psychophysics.

Sandberg M Int Ophthalmol Clin. 1980; 20(1):39-52.

PMID: 6995379 DOI: 10.1007/BF00149254.