Prevention of Dislocation After Hip Arthroplasty: Lessons from Long-term Followup

Overview
Publisher Wolters Kluwer
Specialty Orthopedics
Date 2002 Jan 5
PMID 11764345
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Regarding dislocation after total hip arthroplasty, prevention is worth an ounce of cure. The current authors evaluated dislocation after total hip arthroplasty during the 26-year practice of one surgeon to identify potential variables that can contribute to the prevention of dislocation. Between 1970 and 1996, dislocation after total hip replacement occurred after 7.2% of primary hip arthroplasty procedures (298 of 4164 primary hip replacements) and 11.2% of revision hip arthroplasty procedures (90 of 803 revision hip replacements). Significant findings included an increase in dislocation when 22-mm modular femoral heads were used and a decrease in dislocation after revision for dislocation when constrained liners were used. An additional finding was that 26% of first time dislocations occurred more than 2 years after surgery. Concerning prevention of dislocation, small head modular femoral components should be used cautiously, and constrained liners should be considered in complex revision cases. Patients should be counseled concerning the potential for dislocation many years after their arthroplasty.

Citing Articles

A double mobility acetabular implant for primary hip arthroplasty in patients at high risk of dislocation.

Vasukutty N, Middleton R, Young P, Uzoigwe C, Barkham B, Yusoff S Ann R Coll Surg Engl. 2014; 96(8):597-601.

PMID: 25350182 PMC: 4474101. DOI: 10.1308/003588414X14055925058391.


Impingement and dislocation in total hip arthroplasty: mechanisms and consequences.

Brown T, Elkins J, Pedersen D, Callaghan J Iowa Orthop J. 2014; 34:1-15.

PMID: 25328453 PMC: 4127709.


Acetabular liner with focal constraint to prevent dislocation after THA.

Munro J, Vioreanu M, Masri B, Duncan C Clin Orthop Relat Res. 2013; 471(12):3883-90.

PMID: 23423623 PMC: 3825877. DOI: 10.1007/s11999-013-2858-1.


Relevance of a press-fit dual mobility cup to deal with recurrent dislocation of conventional total hip arthroplasty: a 29-case series.

Saragaglia D, Ruatti S, Refaie R Eur J Orthop Surg Traumatol. 2013; 23(4):431-6.

PMID: 23412147 DOI: 10.1007/s00590-012-1002-3.


The dual mobility socket concept: experience with 668 cases.

Vielpeau C, Lebel B, Ardouin L, Burdin G, Lautridou C Int Orthop. 2010; 35(2):225-30.

PMID: 21184223 PMC: 3032118. DOI: 10.1007/s00264-010-1156-8.