» Articles » PMID: 11707940

Direct Injection Method for Quantitation of Endogenous Leukotriene E4 in Human Urine by Liquid Chromatography/electrospray Ionization Tandem Mass Spectrometry with a Column-switching Technique

Overview
Journal Anal Sci
Publisher Springer
Specialty Chemistry
Date 2001 Nov 16
PMID 11707940
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

A new analytical method employing liquid chromatography/tandem mass spectrometry (LC/MS/MS) with a column-switching system was developed for quantitative determination of leukotriene E4 (LTE4) in human urine. A column-switching system using a trapping column, which concentrates the analyte and removes salts and other water-soluble contaminants, allowed direct injection of human urine. Because simultaneously eluted endogenous contaminants suppressed the ionization efficiency of LTE4, good liquid chromatographic separation was very important for establishing this method, notwithstanding the high selectivity of MS/MS. The calibration curve was linear over the range from 10 to 3000 pg/mL, and the method showed good accuracy and precision. This method should therefore be very useful for determination of LTE4 amounts in human urine in studies on leukotriene metabolism and the efficacy of antileukotriene drugs.

Citing Articles

Effect of a soy isoflavone supplement on lung function and clinical outcomes in patients with poorly controlled asthma: a randomized clinical trial.

Smith L, Kalhan R, Wise R, Sugar E, Lima J, Irvin C JAMA. 2015; 313(20):2033-43.

PMID: 26010632 PMC: 5443623. DOI: 10.1001/jama.2015.5024.


A simple and robust UPLC-SRM/MS method to quantify urinary eicosanoids.

Sterz K, Scherer G, Ecker J J Lipid Res. 2012; 53(5):1026-1036.

PMID: 22338011 PMC: 3329380. DOI: 10.1194/jlr.D023739.


Urinary leukotriene E4/exhaled nitric oxide ratio and montelukast response in childhood asthma.

Rabinovitch N, Graber N, Chinchilli V, Sorkness C, Zeiger R, Strunk R J Allergy Clin Immunol. 2010; 126(3):545-51.e1-4.

PMID: 20816189 PMC: 2935914. DOI: 10.1016/j.jaci.2010.07.008.


Leukotriene-E4 in human urine: Comparison of on-line purification and liquid chromatography-tandem mass spectrometry to affinity purification followed by enzyme immunoassay.

Armstrong M, Liu A, Harbeck R, Reisdorph R, Rabinovitch N, Reisdorph N J Chromatogr B Analyt Technol Biomed Life Sci. 2009; 877(27):3169-74.

PMID: 19726242 PMC: 2753184. DOI: 10.1016/j.jchromb.2009.08.011.


The role of inflammatory mediators in the synergistic toxicity of ozone and 1-nitronaphthalene in rat airways.

Schmelzer K, Wheelock A, Dettmer K, Morin D, Hammock B Environ Health Perspect. 2006; 114(9):1354-60.

PMID: 16966088 PMC: 1570074. DOI: 10.1289/ehp.8373.